Summary of Contents for Unify OpenScape Cordless IP V2
Page 1
OpenScape Cordless IP V2 Administrator Documentation P31003C1020M1000276A9...
Page 2
Provide feedback to further optimize this document to edoku@unify.com. As reseller please address further presales related questions to the responsible presales organization at Unify or at your distributor. For specific technical inquiries you may use the support knowledgebase, raise - if a software support contract is in place - a ticket via our partner portal or contact your distributor.
1 OpenScape Cordless IP V2 – Introduction OpenScape Cordless IP V2 is a DECT multicell system for connecting DECT base stations to a VoIP Communi- cation System. It combines the options of IP telephony with the use of DECT telephones.
Page 6
In future multiple DECT manager integrations, DECT managers could be synchronised by defining synchronisation between clusters of different DECT managers. Deployments The current OpenScape Cordless IP V2 deployment can be used for small to medium DECT networks. Small Medium Base sta-...
OpenScape Cordless IP V2 – Introduction Planning your DECT wireless network DECT man- ager Integrator and DECT manager on the same device Integrator Number of parallel calls depending of device role Base Base + DECT manager Base + DECT manager +...
OpenScape Cordless IP V2 – Introduction OpenScape Cordless IP V2 – overview 1.2 OpenScape Cordless IP V2 – overview Front Device button Set the device role; reset the device p. 12 Antennas Mounting the antennas p. 11 LED displays Operation status of the device p.
Note: The base stations will go offline for the time of firmware update, i.e., that you may have to wait a short time until you can continue with step 8. 8 Configure the base station synchronization p. 31 9 Configure VoIP Communication System or provider p. 39 P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
10Register handsets and perform handset configuration p. 49 All the handsets to be used for making calls over the OpenScape Cordless IP V2 must be registered on the telephone system. Any handset must get assigned an individual SIP account at the SIP Communication System. When registering, the handset is permanently assigned a VoIP connection as the receive and send connection.
Page 11
For each device to be connected to the local network an Ethernet cable is required. The OpenScape Cordless IP V2 is supplied with power via PoE (Power over Ethernet). It must be connected to an Ethernet device with PoE functionality (PoE class IEEE802.3af).
2.4 Defining the device role On delivery all OpenScape Cordless IP V2 devices are configured as base station. To set up the DECT multicell system at least one device must be configured as Integrator/DECT manager. Detailed information on device roles: p.
Page 13
Hang the device on the screws. For outdoor use the device can also be mounted in an outdoor case. Detailed information on installing the outdoor case can be found in the "HiPath Cordless IP – Service Documentation". P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
LED 1 (left) LED 2 (right) Description 0.5 s 0.5 s 0.5 s 0.5 s 0.5 s 0.5 s 0.5 s 0.5 s No DECT base inside active System traffic / ongoing calls P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Ongoing calls are cancelled. In the case of an Integrator/DECT manager the whole configuration is reset. To enable the restoration of your system configuration after a reset, you should regularly save the configuration data to a file ( p. 84). P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Page 16
Operation hints Resetting base stations to factory settings via power procedure P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Configuring the system The web configurator 4 Configuring the system System settings are made via the web configurator of the OpenScape Cordless IP V2 ( p. 17) and cannot be changed using the handsets. This applies in particular for: • Registering and de-registering the handset to the telephone system, handset name.
Page 18
The navigation menu can be displayed permanently or can be hidden in the case the pointer is moved out of the menu area. Use the Auto-hide menu check box beneath the menu list to show/hide the menu. unchecked The navigation menu is shown permanently. (Default) P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Page 19
In the Search in option menu select the columns which should be searched for the entered search item . . . Only entries containing text matching the search item in the selected column are shown in the table. Sorting the list: P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Page 20
The current page is highlighted. Click on Previous or Next to scroll through the list page by page. Click on a specific page number, to go to the desired page directly. P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Page 21
90 Date and time p. 81 Firmware p. 82 Save and restore p. 84 Reboot and reset p. 85 Status Overview p. 87 Statistics Base stations p. 88 Incidents p. 89 P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Page 22
Configuring the system The web configurator P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Enter a label for the device. It is used to identify the device in network communication. Network type Select the IP protocol used in your local network: Currently only IPv4 is supported. P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Page 24
This forwards address requests from the Integrator/DECT manager to its DNS server. There is no default setting for a DNS server. Alternate DNS Enter the IP address for the alternate DNS server that should be used in situations where the preferred DNS server cannot be reached. P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
DECT manager and base stations are not tagged and therefore phone functions are not concerned. If required, you must carry out a hardware reset via power procedure ( p. 15). This means that all settings are lost. P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Page 26
Network administration Local network setting – VLAN P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Name of the base station. When added to the list the MAC address is used as name. The base station located at the same device as the DECT manager is shown as LocalBS. The name can be edited ( p. 29) P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Page 28
Delete it from the Connected base stations list. Open a connection to the intended DECT manager. Assign the base station from the base stations pending list to the DECT manager. P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Page 29
Hardware address of the base station. With this address the device can be uniquely identified within the Ethernet. It cannot be changed DECT manager Name of DECT manager the base station belongs to. Currently always local: The base station belongs to the con- figuring device. P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Page 30
The transmitting power of the external antennas can be reduced. This may be needed in order not to violate emis- sion regulations, in case the device is equipped with external antennas ( p. 11). Click on Yes/No to reduce/not reduce the transmitting power by 8 dB. P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
The synchronisation within a cluster takes place in a master/slave procedure. This means that one base station (sync master) defines the synchronisation cycle for one or more other base stations (sync slaves). P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Page 32
• Configuration of the system is simplified as all base stations can be synchronised on one synchronization master. P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Page 33
• Enhanced packet processing logics (like L3 switching or packet inspection) could have significant negative impact on the resulting packet delay jitter. If possible, they should be deactivated for UNIFY BSIP2 base stations connected switch ports.
Page 34
7 Configuration: Simple LAN synchronisation with base station 4 as LAN master. The DECT level has no rel- evance for this configuration. Base sta- Cluster DECT LAN Mas- Sync tion Level Slave P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Page 35
The base station in the centre of the cluster is on DECT level 1. That reduces the amount of necessary sync levels. Base sta- Cluster DECT LAN Mas- Sync tion Level Slave DECT DECT DECT DECT DECT DECT P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Page 36
LAN. The other base station are synchronised via DECT. As the LAN master must be on DECT level 1 the base station 4 is used as LAN master. Base station Cluster DECT Level LAN Master Sync Slave DECT DECT DECT DECT DECT DECT P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Page 37
The DECT multicell system can manage up to nine clusters. Select the synchronisation level for the base station from the DECT Level option menu. P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Page 38
Currently the LAN master can only be configured on DECT level 1. From the Sync Slave option menu select whether the base station is to be synchronised via DECT or via LAN. For the Sync master leave this column empty. P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Configuring provider and/or PBX profiles Click on next to the name of the VoIP connection you want to edit . . . the provider/PBX configuration page is opened ( p. 40). P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Enter the domain part of the user address (SIP URI). Together which the phone‘s user name it is used to build the Address Of Record (AOR) or to build a destination out of the dialed number. Examples: sip.domain. for john.smith@sip.domain.net 10.100.0.45 for 02871913000@10.100.0.45 P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Page 41
SRTP options Only available if TLS is selected. SRTP (Secure Realtime Protocol) is a security profile to ensure confidentiality, integrity, replay protection and message authentication for audio-visual data transmission over IP-based networks. P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Page 42
Enter the IP address or the (fully qualified) DNS name of the failover registration server. SIP server port Enter the communication port used on the failover registrar. Range: 1-65535; Default: 5060 (for UDP/TCP), 5061 (for TLS) P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Page 43
Enter the communication port used by the outbound proxy. Range: 1-65535; Default: 5060 (for UDP/TCP), 5061 (for TLS) Outbound proxy port is empty and Outbound server address is a name: P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Page 44
VoIP connection is established. Default settings for the codecs used are stored in your phone; one setting optimised for low bandwidths and one for high bandwidths. P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Page 45
Selection of codecs G.722 and G.729 influence the system capacity in direction to lower amount of parallel calls per base station. Number of parallel calls per base station depending on bandwidth Codec Narrow band / wide band Number of calls G711 Narrow band P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Page 46
The P-Asserted-Identity header field is used among trusted SIP entities (typically inter- mediaries) to carry the identity of the user sending a SIP message as it was verified by authentication. Service Codes P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Page 47
In the text fields Call Completion on (CCBS, CCNR)/Call Completion off (CCBS, CCNR) enter the key sequence for activating/deactivating CCBS and CCNR. Click on Set to save the settings of this page. P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Page 48
Provider and PBX profiles Configuring telephony server profiles P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
A VoIP connection is registered for the handset and a connection has been established successfully. There is no VoIP connection configured or it is not possible to estab- lish a connection to the configured VoIP provider. Type Model designation of the handset. P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Registering a set of handsets You can register a set of handsets without restarting the registration mode. Prepare registration for new mobile devices as follows: Enter the actual IPUI and maybe an individual PIN P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Page 51
Enter a PIN in the text field. Value: min. 1, max. 4 digits Click on Generate random PIN . . . a four-digit PIN is generated and shown in the text field. P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Page 52
Specify the SIP authentication (HTTP digest) name. The Authentication name acts as access ID when regis- tering with the SIP proxy/registrar server. It is usually identical to the phone number for the VoIP account. Value: max. 74 characters P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Page 53
Mobile devices Registering/de-registering handsets Authentication password Enter the password for SIP authentication (HTTP digest). The phone needs the password when registering with the SIP proxy/registrar server. Value: max. 74 characters P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Page 54
Select an online directory from the list for Automatic look-up or deactivate this option. When there is an incom- ing call, the caller's name is read from this directory and shown in the display (the availability of this function depends on the online directory provider). P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Page 55
The credentials for the user’s SIP account are used (Authentication name and Authentication pass- word). Network mailbox configuration If a network mailbox is available for the VoIP account assigned to the handset, you have to activate this function. P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Page 56
Select Yes/No next to Missed/accepted calls count, to activate/deactivate the call counter for missed and accepted calls. The information is displayed in the handset’s call lists, missed calls are also shown on the hand- set’s idle display. P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
The page shows the number of mobile devices in registration status To register, Registering and the total number of entries in the mobile devices list, including those in registration status Registered and Not registered. P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Page 58
Single handsets that are rejected have to be registered by a new registration procedure or manually. P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Telephony settings General VoIP settings 9 Telephony settings 9.1 General VoIP settings Settings Telephony VoIP P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Page 60
Upload . . . the file is uploaded and shown in the appropriate list. SIP security password If your private key is protected by a password, enter it here. P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Click on Set to save the settings of this page. To allow users to make wideband calls, the codec G.722 must have been activated for the provider profile that is used for the connection ( p. 45). P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
In case there are problems with transfer especially via transparent proxies, rather than call switching PBX, it might be worth to test with transfer target address derived from transfer target’s transport address. P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Page 63
This means that the access code is set before all phone numbers that do not start with 0 – even when dialling numbers from the directory and other lists. P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Page 64
Tone scheme Select the country or region whose ring tones are to be used for your phone from the option menu. P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
LDAP directory you want to edit . . . the LDAP configuration page is opened p. 65). Configuring an LDAP directory On this page you can edit the data for the selected LDAP directory. P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Page 66
Enter the access data for the LDAP directory in the Username and Password fields (max. 254 characters each). If you want to use individual access data for each handset, the access data is to be set during the handset config- uration ( p. 52). P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Page 67
• The logical operators "&" and "|" are placed before the search criteria. • The search criterion must be placed in brackets and the whole expression must be terminated with a bracket again. • AND and OR operations can be combined. P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Page 68
The user input for City is passed to the LDAP server in the I attribute, the user input for Street is passed in the street attribute. Display format In the Display format field you can stipulate how the search result is to be displayed on the handset. P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Page 69
LDAP server scheme. In order to be able to access attributes or define search filters, you must know the attributes and their designation in the LADP server. The majority of attribute designations are standardised, how- ever specific attributes can also be defined. P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Page 70
LDAP attribute. Multiple attributes can be separated by commas. Examples: Field of a directory entry Attribute name in the LDAP database First name givenName Surname sn, cn, displayName Phone (home) homePhone, telephoneNumber Phone (office) telephoneNumber Phone (mobile) mobile P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Page 71
City I, postalAddress postalCode Country friendlyCountryName, c Additional attribute user-defined Mark the check box Additional attribute can be dialed, if an additional attribute is defined and it is a phone number. P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Enter a new password for the administrator access to the web configurator. Default: admin Repeat password Repeat the new password entered in the New password (Admin) field. Show password To view the entered characters mark the check box near Show password. P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Page 74
The user name for the CLI access is cli. Repeat the new password entered in the CLI Password (Admin) field. Show password To view the entered characters mark the check box next to Show password. P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Used Licenses Number of licenses that are currently used. This can be activated licenses or licenses in grace period. Status SIEL-ID: % % stands for the license ID of an activated license. P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Page 76
License in grace period. % stands for the number of days that left: % are still left to activate the license. Grace period - The grace period has expired. Making calls is no longer possi- expired ble. P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Page 77
Enter the address (URI) of the remote license server. At present, Local CLA is not supported. Updating the license Click on Refresh . . . the license is updated based on the license server P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
The process will take some time and requires a system restart. Connections with mobile devices will be terminated. For security reasons you should save the configuration before you start an auto-configuration pro- cess ( p. 84). P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
The list contains the certificates that have been received from servers but have not passed the certificate check, and certificates from the Server certificates / CA certificates lists that have become invalid. P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Page 80
HTTP digest username Enter the user name for HTTP authentication. Value: max. 74 characters HTTP digest password Enter the password for HTTP authentication. Value: max. 74 characters P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
You can determine the internal time server to act as local time server for your network. Click on Yes/No to determine the internal time server to act/not to act as local time server. Click on Set to save the settings on this page. P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
The date and time are displayed in the format set for that handset. 11.7 Firmware Regular updates to the firmware for the Integrator/DECT manager and base stations are provided by Unify via SWS (Software Supply Server). You can upload these updates onto the Integrator as required.
Page 83
DECT manager you want to edit . . . the DECT manager firmware page is opened. Firmware update configuration is carried out analogous to the configuration for the local system. P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
• The old device must no longer be in operation. • The firmware version of the new device must correspond, at least, with the version of the device from which the data is saved, including the set patches. P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
The device is a Integrator/DECT manager. The network configuration is set to dynamic IP. All in one - static IP The device is a Integrator/DECT manager. The network configuration is set to the following static IP settings: P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Page 86
The Save and restore page is opened allowing you to save the current configuration on your com- puter ( p. 84). The reset procedure starts at once. The current configuration will be lost. Cancel The reset procedure is interrupted. P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Diagnostics and troubleshooting Status information 12 Diagnostics and troubleshooting 12.1 Status information The web configurator provides a status page with important information on the multicell system operation and the connected devices. Status Overview P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
DECT Level Synchronisation level, synchronisation allowed with any lower sync level From / To Time period of the statistical data collection for this base station Conn Number of connections, i.e. calls made P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Click on the View option menu on the right Select the columns you want to be displayed in the table ( = displayed/hidden). Names of columns which cannot be hidden are greyed out. 12.3 Incidents Status Statistics Incidents P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
12.4 System log and SNMP manager The system report (SysLog) gathers information about selected processes performed by the DECT manager and base stations during operation and sends this to the configured SysLog server. Settings System System log P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Page 91
To gather management and statistic information concerning base station events via an SNMP manager you have to enter the address information. SNMP manager address Enter the IP address of the SNMP manger. SNMP manager port Enter the port number. P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Page 92
Diagnostics and troubleshooting System log and SNMP manager P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Each handset is assigned a send and receive connection ( p. 52). If your OpenScape Cordless IP V2 is connected to a PBX that permits the formation of groups, VoIP connections can also be assigned to groups. In this case, you will also receive calls on your handset that have been sent to your group number.
Page 94
Enter the service code defined for the PBX/provider, e.g., *6 If you decide you do not want a ringback, you can switch the function off again: Enter the service code defined for the PBX/provider, e.g., #6 P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
End active call OK . . . the connection to the first caller is reactivated Press the End call key . . . a recall to the first participant is initiated P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Page 96
End call (during a conversation or before the second participant has answered) . . . the call is transferred Call transfer options must be set correctly for the PBX/provider ( p. 44). P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Depending on the handset used you can access all available directories also via the handset's menu: . . . use to select Directory Local directory . . . use to select Net Directories List of all online directories set up on the telephone system P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
The directories are displayed with the names specified in the web configurator. Example for handling a corporate directory on the handset ( p. 105). If handsets are connected to a OpenScape Cordless IP V2, it is not possible to transfer entries from the local directory to another handset.
The LDAP Search base (BaseDN) parameter specifies the starting point for the search in the LDAP directory tree. This starting point must be defined on the LDAP server and entered here for the LDAP client according to the P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Page 100
For the meaning of the objects, see section Filters ( p. 101). Examples: Starting point: Object PhoneBook, in the domain example.com Definition: cn=PhoneBook,dc=example,dc=com Starting point: Object PhoneBook in the subdirectory sales/support, in the domain example.sales.com. Definition: cn=PhoneBook,o=support,ou=sales,dc=example,dc=sales,dc=com P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
• Additional filters can be defined to enable detailed search The LDAP protocol offers various setting options for filters and search functions, e.g. wildcards, fixed character strings and further operators. For full details see the RFC 4515. P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Page 102
(\) and a 2-digit hex ASCII code as follows: Special character ASCII code Special character ASCII code & < > Example (givenName=James \28Jim\29) will find any entry with givenName attribute's value equal to "James (Jim)" P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Page 103
The attributes telephoneNumber, mobile and homePhone are used for the search. If you enter the numbers "1234567" when dialling, the phone searches the LDAP data- base for entries with the private or mobile or work number "1234567". P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
In the Additional attribute field, you can enter an additional attribute that is available in the LDAP database and should be displayed. If the attribute is a number to be dialled, the option Additional attribute can be dialled must be checked. P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Directory 3 . . . use to select the directory Directory 4 Directory 5 The phone initiates a query to the LDAP server defined in the web configurator. Directory 6 Back P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Page 106
Phone Street: (home), Phone (office) or Phone (mobile). Avenue 12 Press the Talk key . The number is dialled. Back P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Comprehensive user guides for all telephones and telephone systems as well as for accessories can be found online at www.unify.com in the Support category. We thereby help to save paper while providing fast access to the complete up-to-date documentation at any time.
Page 108
The statements quoted above are only fully valid for equipment which is installed and sold in the countries of the European Union and is covered by the directive 2002/96/ EC. Countries outside the European Union may impose other regulations regarding the disposal of electrical and electronic equipment. P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Technical data Specifications B Technical data B.1 Specifications B.1.1 Power consumption Operation as OpenScape Cordless IP V2 (DECT Manager) < 4 W Operations as BSIP2 (Base station) < 4 W B.1.2 General specifications DECT Manager and base stations Power over Ethernet PoE IEEE 802.3af <...
Page 112
99 VoIP account registration data 52 User ID 99 Handsets LDAP server scheme 69 administration 49 LDAP server, URL 65 registered 49 LED displays 8 Help function, web configurator 19 LEDs 14 P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Page 113
Registering, with web configurator 18 ou, attribute 71, 104 Registration centre 57 Outbound proxy mode 43 Registration refresh time 41 Outbound proxy port 43 Registration server 41 Outbound server address 43 Registration server port 41 P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Page 114
17 via LAN 32 working with lists 19 Synchronisation hierarchy 32 examples 34 Synchronisation planning 31 Synchronisation status base station 14, 28 SysLog 90 System configuration 17 System report (SysLog) 90 P31003C1020M1000276A9, 01/2018 OpenScape Cordless IP V2, Administrator Documentation...
Need help?
Do you have a question about the OpenScape Cordless IP V2 and is the answer not in the manual?
Questions and answers