7.1

Description of individual functions

7.1.1
Automatic switch-off function „AUTO OFF"
The crane scales are switched off automatically, when the keyboard is not actuated
and when in the set switch-off time no change of weight has been measured. In order
to finish the Auto-Off mode, press any key on the keyboard or on the remote control.
Call up function "F9 Of", see chapter 7
Press the ZERO key, the current setting appears.
Select the desired setting using the TARE-key.
F9 OF
Of 0
Of 3
Of 5
Of
15
Of
30
Confirm entry by ZERO button.
Use M+ key to return to the weighing mode.
7.1.2

Display background illumination

In weighing mode press and hold the ZERO key, until the current setting appears.
Select the desired setting using the TARE-key.
bl on
Continuous background lighting
bl of
Background illumination off
bl Au
Automatic background illumination only when loaded or key pressed.
Confirm entry by ZERO button.
7.1.3

Check overload records

Call up function „F10 ovEr", see chapter 7
Press the ZERO key to confirm, the display will show the overload number
Press ZERO key again, the date / time and the overload weight will be show in
turn.
Using the TARE-key to select the overload number one by one, and press ZERO
key to check the overload information you select.
30
Function deactivated
Balance will be turned off after 3 min.
Balance will be turned off after 5 min.
Balance will be turned off after 15 min.
Balance will be turned off after 30 min.
HFD-BA-e-1820