Rooftop Installation (Interlocking Tile, Plain Tile); Standard Delivery; Standard Dimensions; Snow Loads - Wolf CFK-1 Installation, Operating And Maintenance Instructions

Rooftop installation with aluplus installation system, roof integration flat roof installation with aluplus installation system. high performance solar collector.
Table of Contents

Advertisement

Standard delivery, fixing material subject to the number of:
Top roof hooks
Bottom roof hooks
with fixing brackets
with fixing brackets
Positioning the collector
array for rooftop
installation
Standard dimensions for
determining the width of the
collector array
Number of collectors
Width [m] installation on end
Max. snow load when installing flat-plate collectors on end with an inclination of 30° to 45°
CFK-1
Max. area loading
Snow load zone 1
Snow load zone 1a
Snow load zone 2
Snow load zone 2a
Snow load zone 3
This calculation takes a factor of 0.8 according to DIN 1055-5 into consideration (corresponding to a roof
inclination of 0° to 30°). We recommend roof integration where higher snow loads prevail.
3062815_0110
6. Rooftop installation
(interlocking tile, plain tile)
Mounting rail
Distribute all roof hooks supplied evenly over the width of the collector
NB
array to spread the loads applied. For this, position the roof hooks as
near to the rafters as possible.
NB: No consideration has been given to the installation location or the pipe
connections.
1
2
X
2.23
3.36
Without snow load extension set
2.4 kN/m²
1190 m above sea level
1039 m above sea level
768 m above sea level
663 m above sea level
587 m above sea level
Mounting rail joint
Screws, nuts, grub
set (if required)
screws, woodscrews
in a bag
3
4
5
6
4.49
5.62
6.75
With snow load extension set
4 kN/m²
1561 m above sea level
1374 m above sea level
1027 m above sea level
896 m above sea level
799 m above sea level
Accessories
Compensating
rail set with
woodscrews for
mounting on rafters
7
8
9
10
7.88
9.01
10.14 11.27