Rooftop Installation (Interlocking Tile, Plain Tile) Roof Hooks On Battens - Wolf CFK-1 Installation, Operating And Maintenance Instructions

Rooftop installation with aluplus installation system, roof integration flat roof installation with aluplus installation system. high performance solar collector.
Table of Contents

Advertisement

Roof hook installation on battens (example for 2 collectors)
Fitted top roof hook
Mounting
rail
M8x20
coach bolt
10
7. Rooftop installation (interlocking tile,
plain tile) roof hooks on battens
If required, trim or bend
the roof hook over
Max. 0.4 m
Rail protrusion
Collector array width
1. Assemble the bottom roof hooks as per the diagram and hook them onto
the batten.
2. Assemble the top roof hooks as per the diagram and hook it onto the batten.
Create the distance between both rails of 2.06 m for collector installation on end at
the top roof hooks using the slot in accordance with the diagram and secure that
position with M8x20 coach bolts.
3. Adjust the height of the fixing brackets and secure with coach bolts M8x20,
ensuring that the pressure is evenly distributed over the roof tiles.
4. Thread the coach bolts M8x20 in sufficient numbers into the mounting
rails.
5. Fit the mounting rails with washer nuts onto the roof hooks.
6. Cover the roof hook area with tiles.
Mounting rail
Max. 0.4 m
Rail protrusion
M8x20
coach bolt
Min. 3
rows
Option
Snow load
extension set
Fit hooks bottom/top
Mounting
rail
Fitted bottom
roof hook
Mounting rail
Coach bolt
M8x20
Washer nut
M8
3062815_0110