Rooftop Installation; Interlocking Tiles, Plain Tiles - Wolf CFK-1 Installation, Operating And Maintenance Instructions

Table of Contents

Advertisement

Special features for interlocking or plain tile roofs
Roof hook installation on battens (example for 2 collectors)
Fitted top roof hook
Mounting rail
M8 x 20 coach bolt
Collector array width
3062815_201508

Rooftop installation -

Interlocking tiles, plain tiles

If required, trim or bend
the roof hook over
Max. 0.4 m
rail protrusion
Distribute all roof hooks supplied evenly over the width of the collector
CAUTION
array to spread the loads applied. For this, position the roof hooks as
near to the rafters as possible.
1. Assemble the bottom roof hooks in acc. with the diagram and hook them
into the batten.
2. Assemble the top roof hooks in acc. with the diagram and hook them into
the batten.
Create the distance between both rails of 2.06 m for collector installation
on end or 1.06 m for collector installation across at the top roof hooks
using the slot in accordance with the diagram and secure that position with
M8 x 20 coach bolts.
3. Adjust the height of the fixing brackets and secure with M8 x 20 coach bolts,
ensuring that the pressure is evenly distributed over the roof tiles.
4. Slip the M8 x 20 coach bolts in sufficient numbers into the mounting rails.
5. Fit the mounting rails with washer nuts onto the roof hooks.
6. Cover the roof hook area with tiles.
Mounting rail
Mounting rail
Max. 0.4 m
rail protrusion
Min. 3 rows
Option
Snow load
extension set
Fit hooks bottom / top
Fitted bottom
roof hook
Mounting rail
M8 x 20 coach bolt
M8 washer nut
>15°
13

Advertisement

Table of Contents
loading

Table of Contents