Wolf CFK-1 Installation, Operating And Maintenance Instructions page 24

Rooftop installation with aluplus installation system, roof integration flat roof installation with aluplus installation system. high performance solar collector.
Table of Contents

Advertisement

Construction
Timber spacers (in the
thickness of the battens
less 9 mm)
Mounting rail
Flashing tape
Waterproof subroof
Installation and extension of the
lower mounting rail
8 x 80
Drill a Ø 5 mm hole and secure the mounting rail with the hexagon head cap wood screw 8x80 and the timber spacers (batten
thickness less 9 mm) to the rafters.
Affix the flashing tape in accordance with the diagram. For this, remove the protective foil only in the area actually to be used for
the mounting rail. The flashing tape must protrude on the left and right approx. 25 cm over the flashing tape bases. Secure several
flashing tapes to each other with an overlap of at least 5 cm. (Do not as yet affix the flashing tape to the tiles as the collectors must
still be secured to the mounting rail.)
24
14. Roof integration, slate roof
Timber spacers (in the thickness of the battens)
Top panel
Collector
Flashing tape base,
L.h.
2 x coach bolts
M8 x 16
Timber spacer
(batten thickness less 9 mm)
Connecting rail
4 x coach bolts M8 x 16
Mounting rail for 2
collectors (2.26 m)
Recommendation
Stuff the space below
the top panel at the tile
contact point to prevent
the tile from pushing
through.
Flashing tape base, R.h.
Mounting rail for 1 additional
collector (1.13 m)
Flashing tape
Mounting
rail
Overlap > 5 cm
3062815_0110

Advertisement

Table of Contents
loading

Table of Contents