EQUIPMENT TURNS ON AT AN UNEXPECTED TIME
1.
At the Cp3000 Controller, verify that the problem is not program-related. If you see PROG 1 while reviewing
programs, then that equipment has more than one program. Press same Equipment Key again to view additional
programs. Cancel programs as needed.
2.
It is normal for the freeze protection circuitry to turn equipment on when the temperature falls to 35 ° Fahrenheit.
At the Lx3000 circuit board, locate 7-position "FREEZ PROT" Program Switch, and determine which circuits
have been selected for freeze protection.
SPA-SIDE REMOTE NOT WORKING
At the Cp3000 Controller, locate the "Remote Control at Spa" Key (behind right-side door), and verify that status lamp
is on.
SPA-SIDE EQUIPMENT TURNS OFF AFTER 30 MINUTES
This is a normal function for Aux5 and Aux6 circuits. If you would like to disable this function, adjust the 3-position
S1 Program Switch which is located at center right-side of the Cp3000 circuit board (see SPA-SIDE COUNTDOWN
TIMER for details).
NO DISPLAY AT Cp3000
1.
At the Lx3000 Power Center, verify Auto/Service Status Lamp is illuminated (this confirms there is power to the
system).
2.
Unplug communication cable from Cp3000 and Lx3000 circuit boards. Temporarily transfer Cp3000 Controller
to equipment site, and use 4' test cable (included with system) to interconnect Cp3000 with Lx3000.
3.
If the test cable activates the Cp3000 display, repair or replace communication cable.
ABNORMAL OPERATION
Re-setting the Cp3000:
1.
Remove Cp3000 control panel from wall.
2.
Disconnect 6-conductor communication cable.
3.
Locate resetting pins on lower right hand corner of circuit board.
4.
Unplug shorting plug from "NORMAL" position, and insert into "RESET" position.
5.
Return shorting plug to "NORMAL" position.
6.
Reconnect 6-conductor communication cable.
7.
Re-install Cp3000 control panel.
This has reset the Cp3000 circuit board. Be sure to reset the Clock Time, Programs, and Sensor Calibration.
Re-setting the Lx3000
Turn system power off (momentarily trip system circuit breaker at sub-panel). This will reset the Lx3000 circuit board.
38
Problem Solving
Need help?
Do you have a question about the CP3000 and is the answer not in the manual?