Maintenance - Compool CP3000 Installation & Operating Instructions Manual

Pool-spa control system
Table of Contents

Advertisement

Compool Cp3000
CLEANING THE SPA
For cleaning or maintenance purposes, it is possible to use the Control System to automatically empty your spa and
then to refill with clean water from your pool.
At the Lx3000 Power Center:
1.
Press Auto/Service Key to switch the system to "Service" mode.
2.
Press Key #S until "Drain" Status Lamp is illuminated.
3.
Press Key #P (Filter Pump) to turn the filter pump on. The spa will begin to drain into the pool.
Caution: Do not leave equipment unattended when draining or filling the spa.
4.
Before the spa has drained completely, press Key #P (Filter Pump) to turn the filter pump off. The spa will stop
draining, and cleaning can now commence.
Note: The spa should not be drained completely, or prime will be lost.
5.
When cleaning is complete, press Key #S until "Fill" Status Lamp is illuminated.
6.
Press Key #P (Filter Pump) to turn the filter pump on. The spa will begin to fill with clean water from the pool.
7.
When the spa water level has returned to normal, press the Auto/Service Key to switch the system back to "Auto"
mode.
ADDING CHEMICALS
When adding chemicals to the water it is possible to override the daily equipment operation cycles, and activate (or
shut-off) the filter pump for a 3-Hour period. See 3-HOUR FILTER OVERRIDE for details.
WINTERIZING THE SYSTEM
During the winter season, it is possible to disable the pool from your control system, but still be able to use your spa.
Consult a qualified service company to winterize your pool and protect the plumbing from freeze damage.
The following procedure will disable the pool equipment:
1.
At the Lx3000 Power Center, press the Auto/Service Key to switch the system to "Service" mode, and press Key
#S until "Spa" Status Lamp is illuminated.
2.
Flip toggle switch on back of Intake and Return Valve Actuators to OFF.
3.
At the Lx3000 Power Center, press Auto/Service Key to return system to "Auto" mode.
4.
At the electrical supply panel, turn off the pool cleaner circuit breaker (if applicable).
5.
At the Cp3000 Controller, press the Pool Heat Source Key until "Off" Status Lamp is illuminated.
6.
If your control system incorporates solar, ensure that the panels are completely drained. To inactivate the Solar
Temperature Sensor, it is necessary to adjust the "FEATURES" Program Switch, which is located at top center of
Lx3000 circuit board. Use the corner of a small screwdriver or other blunt instrument to slide Switch #1
(SOLAR) to the OFF position.

MAINTENANCE