4.2 C1, C2 and C3 cable wires signal description, configuration jumpers
C1 cable
#
Color
1
Blue
2
Red
3
Pink
4
Yellow
5
Grey
6
Black
7
White
8
Green
C2 cable
Color
#
1
Pink
2
Brown
Orange
3
4.1 LED Indicators
D1
Red-green
D2
Yellow
D3
Green
4.2 Standard connection
Input 1
Input 2
Output 1
Output 2
I/O Port
Meaning
0 V (GND)
+12 VDC power supply
Alarm output
Input 1 (IN1)
Input 2 (IN2)
RS 485 – A wire
RS 485 – B wire
Input/output 3 (IO3)
Meaning
NO relay contact
C relay contact
NC relay contact
Table 6: Wiring description, configuration jumpers
Continuously lit (red)
Flashing with 4 s period (red)
Fast switching (red / green)
Single flash (green)
Continuously lit / flashing
Short flashing with 1s per.
Door contact, active when door closed; REX button
Request to exit button or handle contact; Tamper; Disabling function;
active on 0 VDC
Door lock control (relay)
Alarm status signaling (+ 5V on any alarm occurrence)
External tamper (Standard operating mode)
External reader buzzer control (op. mode with entry reader)
Disabling function
Reading synchronization: MASTER / SLAVE mode
Page 6
C3 cable
#
Color
Meaning
1
Blue
0 V (GND)
2
Red
+12 VDC power supply
3
Yellow
Input 1 (IN1)
4
Grey
Input 2 (IN2)
5
Black
Wiegand data 0
6
White
Wiegand data 1
7
Green
Input/output 3 (IO3)
Configuration jumpers
#
Meaning
RS 485 line terminating resistor
J0
(=150 between A and B wires)
Online operating mode
Offline operating mode
Address setting mode;
RS 485 BUS testing mode
ID media reading
Programming mode
Indicating door lock release
(configurable)
Indicating door lock release
Table 7: LED indicators
Table 8: Standard connection