Industrial Electronic Devices
UPDATE DEVICE:
By pressing the
"Update
Device" button, it is possible to load the created Configuration into the
device; and also the Firmware, if necessary.
If you don't know the actual IP address of the device you have to use this procedure:
Connect the USB cable;
Connect the Ethernet cable;
Turn ON the converter;
Insert the IP "192.168.2.205";
Press the "Ping" button, "Device Found! must appear";
Press the "Next" button;
Select which operations you want to do;
Press the
"Execute update
When all the operations are "OK", the updating is done;
Remove the USB cable;
If you know the actual IP address of the device, you have to use this procedure:
Turn ON the Device with the Ethernet cable inserted;
Insert the actual IP of the Converter;
Press the "Ping" button, must appear "Device Found!";
Press the "Next" button;
Select which operations you want to do;
Press the
"Execute update
When all the operations are "OK" the device automatically goes at Normal Mode.
At this point the configuration/firmware on the device is correctly updated.
ADFweb.com Srl – IT31010 – Mareno – Treviso
firmware" button to start the upload;
firmware" button to start the upload;
User Manual DMX / PROFINET - Converter
Document code: MN674-A028_ENG
Figure 5: "Update Device" windows
INFO:
www.adfweb.com
Revision 1.000 Page 17 of 28