Installation; Appliance Installation; Water Connection; Power Supply - STIEBEL ELTRON UFP 5 t Si Operation And Installation

Open vented (non-pressurised) small water heater
Table of Contents

Advertisement

Available languages

Available languages

INSTALLATION

Installation
9.
Installation
9.1

Appliance installation

f Mark out the holes to be drilled on the wall (see chapter "In-
f
stallation / Specification / Dimensions and connections").
f Drill the holes and insert suitable rawl plugs.
f
f Secure the wall mounting bracket using suitable screws.
f
f Hang the appliance on the wall mounting bracket.
f
Note
Surplus cable can be stored in the cable compartment.
9.2

Water connection

Material losses
!
Carry out all water connection and installation work in
accordance with regulations.
Material losses
!
Counterhold with a suitable spanner when tightening
fittings.
www.stiebel-eltron.com 
Material losses
!
The appliance may develop a leak and cease functioning.
f Never subject the appliance to water pressure.
f
f Never interchange the water connections.
f
f Set the flow rate (see tap instructions). Observe the
f
maximum permissible flow rate with a fully opened
tap (see chapter "Installation / Specification / Data
table").
Match up the colour coding on the tap water connections and the
appliance:
- R.h. side blue = "Cold water inlet"
- L.h. side red = "DHW outlet"
f Secure the water connections from the tap to the appliance.
f
Note
Ensure that the water connections are not kinked during
installation. Prevent any tensioning during installation.
9.3

Power supply

WARNING Electrocution
Carry out all electrical connection and installation work
in accordance with relevant regulations.
WARNING Electrocution
When permanently connected to the power supply using
a dedicated junction box, the appliance must be able to
be isolated from the mains power supply by an isolator
that disconnects all poles with at least 3 mm contact
separation.
WARNING Electrocution
Ensure that the appliance is earthed.
Material losses
!
The voltage specified on the type plate must match the
mains voltage.
f Observe the type plate.
f
The following electrical connections are permissible:
Connection to a freely accessible standard socket with
matching plug
Permanent connection to an appliance junction box
with earth conductor
UFP 5 t Si