Safety

INSTALLATION
6.
Safety
Only a qualified contractor should carry out installation, commis-
sioning, maintenance and repair of the appliance.
6.1

General safety instructions

We guarantee trouble-free function and operational reliability only
if original accessories and spare parts intended for the appliance
are used.
6.2

Instructions, standards and regulations

Note
Observe all applicable national and regional regulations
and instructions.
7.

Appliance description

The open vented (non-pressurised) appliance is only suitable
for undersink installation. The appliance is intended to heat cold
water and supply it to a single draw-off point.
The appliance must only be installed with an open (non-pres-
surised) tap.
7.1

Standard delivery

Delivered with the appliance are the following:
- Wall mounting bracket
7.2

Required accessories

Select an open (non-pressurised) tap that is appropriate for your
requirements and equipment:
Mixer taps
- WST, WUT
Mono lever mixer taps
- MEW, MES, MEWC
Sensor tap
- WEN
14
|  UFP 5 t Si 
8.

Preparations

f Flush the water line thoroughly.
f
Water installation
A safety valve is not required.
Taps/valves
Sealed unvented taps are not permitted.
f Install an open vented tap.
f
8.1

Installation site

Material losses
!
Install the appliance in a room free from the risk of frost.
Material losses
!
Mount the appliance on the wall. The wall must have a
sufficient load-bearing capacity.
Note
The appliance is only suitable for undersink installation.
The water connections of the appliance point upwards.
Note
Ensure that the appliance is freely accessible for main-
tenance work.
Always install the appliance vertically and near the draw-off point.