Intended Use; Safety Instructions; Appliance Description; Function - STIEBEL ELTRON SNO 5 Plus GB Manual For Operation And Installation

Small water heater (non-pressurized)
Hide thumbs Also See for SNO 5 Plus GB:
Table of Contents

Advertisement

Appliance description

Signal
Meaning
word
WARNING Failure to observe this information may result in
death or serious injury.
CAUTION Failure to observe this information may result in
moderate or minor injury.
NOTICE
Failure to observe this information may result in
property damage, consequential losses or environ-
mental damage.
3.2

Intended use

This open vented (non-pressurised) appliance is designed for
heating domestic hot water. The appliance can supply one
draw-off point. The appliance must only be installed with an
open (non-pressurised) tap.
The product is designed for domestic use. It can be used safely
by untrained persons. This product can also be used in a non-
domestic environment, e.g. in a small business, as long as it is
used in the same way.
Observation of these instructions and of instructions for any ac-
cessories used is also part of the intended use of this appliance.
Property damage
The appliance is designed for oversink installation.
u During installation, the water connections of the
appliance must point downwards.
3.3

Safety instructions

– There is a risk of scalding at outlet temperatures in excess
of 43 °C.
– The temperature selector should only be removed by a
qualified contractor.
– Warning for Australia and New Zealand – This appliance
may deliver water at high temperature. Refer to the plumb-
ing code of Australia (PCA), local requirements and installa-
tion instructions to determine if additional delivery temper-
ature control is required.
– Where children or persons with limited physical, sensory or
mental abilities are allowed to use this appliance, we re-
commend a permanent temperature limit. A qualified con-
tractor can set this limit.
Possible property damage
– Frost can destroy the appliance and the connected tap. Pro-
tect the appliance and the tap against frost.
– Warning – For continued safety of this appliance it must be
installed, operated and maintained in accordance with the
manufacturer's instructions.
– Never subject the appliance to water pressure. The tap out-
let has a vent function. Scale build-up can block the outlet
and subject the appliance to pressure.
– Never block the tap outlet.
– Only use special aerators for non-pressurised water
heaters.
– Never extend the tap outlet with a tap hose.
– Connecting the appliance via an external switching facility
such as a time switch will cause an unintentional reset of
the high limit safety cut-out. The appliance must not be
connected to a power circuit that is regularly switched on
and off by a device.
4
| SNO 5 - 10 Plus GB
NOTICE
– Only a qualified contractor should carry out installation,
commissioning, maintenance and repair of the appliance.
– Unsuitable spare parts and accessories may jeopardise the
safety of the product and persons using the appliance. Al-
ways use original spare parts and original accessories.
4
Appliance description
4.1

Function

The open vented (non-pressurised) appliance is suitable only for
oversink installation. The appliance is intended to heat cold wa-
ter for supplying a single draw-off point. It must only be used
with a non-pressurised tap.
4.2

Standard delivery

The following are delivered with the appliance:
– Wall mounting bracket
– Drilling template
4.3

Required accessories

A non-pressurised tap must be used for open vented operation
of the appliance. STIEBEL ELTRON offers a wide range of suit-
able taps.
5

Installation (qualified contractors)

5.1

Installation site

Property damage
The water in the appliance may freeze and damage
the cylinder and connections by expansion.
u Only install the appliance in a room free from the
risk of frost.
Property damage
u Mount the appliance on the wall. The wall must
have sufficient load bearing capacity.
Property damage
The appliance is designed for oversink installation.
u During installation, the water connections of the
appliance must point downwards.
Ensure that the appliance is freely accessible for
maintenance work.
Property damage
Connecting pipe length (from tap to appliance) must
not exceed 1 m.
For connection pipes >1 m:
u Install a tube aerator attachment in the overflow
line.
Always install the appliance vertically and near the draw-off
point.
NOTICE
NOTICE
NOTICE
NOTICE
www.stiebel-eltron.com