STIEBEL ELTRON SHC 10 Operation And Installation

STIEBEL ELTRON SHC 10 Operation And Installation

Sealed unvented pressurised small water heater

Advertisement

OPERATION AND INSTALLATION
UTILISATION ET INSTALLATION
GEBRUIK EN INSTALLATIE
OBSLUHA A INSTALACE
OBSŁUGA I INSTALACJA
ЭКСПЛУАТАЦИЯ И УСТАНОВКА
Sealed unvented (pressurised) small water heater | Petit chauffe-eau ECS (sous
pression) | Gesloten (drukvaste), kleine warmwaterboiler | | Malý tlakový zásobník
teplé vody | Mały, ciśnieniowy, pojemnościowy ogrzewacz | Малогабаритный
накопительный водонагреватель закрытого типа (напорный)
» SHC 10
» SHC 10 GB Eltron
» SHC 15 Stiebel
» SHC 15 GB Eltron

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SHC 10 and is the answer not in the manual?

Questions and answers

Summary of Contents for STIEBEL ELTRON SHC 10

  • Page 1 | Gesloten (drukvaste), kleine warmwaterboiler | | Malý tlakový zásobník teplé vody | Mały, ciśnieniowy, pojemnościowy ogrzewacz | Малогабаритный накопительный водонагреватель закрытого типа (напорный) » SHC 10 » SHC 10 GB Eltron » SHC 15 Stiebel » SHC 15 GB Eltron...
  • Page 2: Table Of Contents

    Descaling the appliance ��������������������������������������� 10 14.8 Replacing the power cable ����������������������������������� 10 - Regularly activate the safety valve to prevent 14.9 Checking the earth conductor �������������������������������� 10 it from becoming blocked, e.g. by limescale deposits. | SHC 10 | SHC 15 www.stiebel-eltron.com...
  • Page 3: Operation

    Any other use beyond that described shall be deemed inappropri- Injury ate. Observation of these instructions and of instructions for any accessories used is also part of the correct use of this appliance. Electrocution Burns (burns, scalding) www.stiebel-eltron.com SHC 10 | SHC 15 |...
  • Page 4: General Safety Instructions

    See type plate on the appliance. = Cold. On this setting, the appliance is protected from frost. The tap, water lines and safety valve are not pro- tected. MAX = Highest selectable temperature | SHC 10 | SHC 15 www.stiebel-eltron.com...
  • Page 5: Cleaning, Care And Maintenance

    SHC 10 | SHC 15 Stiebel O-No. 000000 - Two reducers from G 1/2 to G 3/8 F-No. 0000 - 000000 SHC 10 GB Eltron | SHC 15 GB Eltron - Two locking ring fittings G 1/2 x 15 Accessories SHC 10 | SHC 15 Stiebel - Safety assembly G 1/2 (optional) www.stiebel-eltron.com...
  • Page 6: Preparations

    The safety valve drain must remain open to the atmosphere. f Fit a pressure reducing valve upstream of the safety valve in the cold water supply line if the supply pressure is > 0.48 MPa. | SHC 10 | SHC 15 www.stiebel-eltron.com...
  • Page 7: Water Connection

    INSTALLATION Installation Water connection SHC 10 GB Eltron | SHC 15 GB Eltron Material losses Carry out all water connection and installation work in accordance with regulations. Material losses The appliance may lose its function. f Never interchange the water connections.
  • Page 8: Commissioning

    Loud boiling noises The appliance is scaled Descale the appliance. inside the appliance. Water drips from the The safety valve is Clean / descale the valve seat. safety valve after scaled up or dirty. heat-up. | SHC 10 | SHC 15 www.stiebel-eltron.com...
  • Page 9: Activate High Limit Safety Cut-Out

    Disconnect all wires from the combined temperature control- ler/high limit safety cut-out. f Drain the appliance via its connectors. f Remove the combined temperature controller / high limit safety cut-out from the flanged immersion heater. f Remove the flanged immersion heater. www.stiebel-eltron.com SHC 10 | SHC 15 |...
  • Page 10: Checking The Protective Anode And Replacing If

    Secure the protective anode with a contact washer and nut to a torque of 11±1.2 Nm. | SHC 10 | SHC 15 www.stiebel-eltron.com...
  • Page 11: Specification

    15.2 Wiring diagram 1/N/PE ~ 220-240 V 15.1 Dimensions and connections SHC 10 | SHC 15 Stiebel 15.3 Heat-up diagram The heat-up period depends on the degree of scaling and residual heat. For the heat-up time for a cold water supply at 10 °C and a maximum temperature setting, see the diagram.
  • Page 12: Details On Energy Consumption

    Steel, enamelled Thermal insulation material Casing material Colour White White White White Connections Water connection G 1/2 A G 1/2 A G 1/2 A G 1/2 A Dimensions Depth Height Width Weights Weight | SHC 10 | SHC 15 www.stiebel-eltron.com...
  • Page 13 This will not affect warranties issued by any importers. Environment and recycling We would ask you to help protect the environment. After use, dispose of the various materials in accordance with national regulations. www.stiebel-eltron.com SHC 10 | SHC 15 |...
  • Page 14   Deutschland Verkauf Tel. 05531 702-110 | Fax 05531 702-95108 | info-center@stiebel-eltron.de STIEBEL ELTRON GmbH & Co. KG Kundendienst Tel. 05531 702-111 | Fax 05531 702-95890 | kundendienst@stiebel-eltron.de Dr.-Stiebel-Straße 33 | 37603 Holzminden Ersatzteilverkauf Tel. 05531 702-120 | Fax 05531 702-95335 | ersatzteile@stiebel-eltron.de Tel.

This manual is also suitable for:

Shc 10 gb eltronShc 15 stiebelShc 15 gb eltron