Descaling the appliance ��������������������������������������� 10 14.8 Replacing the power cable ����������������������������������� 10 - Regularly activate the safety valve to prevent 14.9 Checking the earth conductor �������������������������������� 10 it from becoming blocked, e.g. by limescale deposits. | SHC 10 | SHC 15 www.stiebel-eltron.com...
Any other use beyond that described shall be deemed inappropri- Injury ate. Observation of these instructions and of instructions for any accessories used is also part of the correct use of this appliance. Electrocution Burns (burns, scalding) www.stiebel-eltron.com SHC 10 | SHC 15 |...
See type plate on the appliance. = Cold. On this setting, the appliance is protected from frost. The tap, water lines and safety valve are not pro- tected. MAX = Highest selectable temperature | SHC 10 | SHC 15 www.stiebel-eltron.com...
The safety valve drain must remain open to the atmosphere. f Fit a pressure reducing valve upstream of the safety valve in the cold water supply line if the supply pressure is > 0.48 MPa. | SHC 10 | SHC 15 www.stiebel-eltron.com...
INSTALLATION Installation Water connection SHC 10 GB Eltron | SHC 15 GB Eltron Material losses Carry out all water connection and installation work in accordance with regulations. Material losses The appliance may lose its function. f Never interchange the water connections.
Loud boiling noises The appliance is scaled Descale the appliance. inside the appliance. Water drips from the The safety valve is Clean / descale the valve seat. safety valve after scaled up or dirty. heat-up. | SHC 10 | SHC 15 www.stiebel-eltron.com...
Disconnect all wires from the combined temperature control- ler/high limit safety cut-out. f Drain the appliance via its connectors. f Remove the combined temperature controller / high limit safety cut-out from the flanged immersion heater. f Remove the flanged immersion heater. www.stiebel-eltron.com SHC 10 | SHC 15 |...
15.2 Wiring diagram 1/N/PE ~ 220-240 V 15.1 Dimensions and connections SHC 10 | SHC 15 Stiebel 15.3 Heat-up diagram The heat-up period depends on the degree of scaling and residual heat. For the heat-up time for a cold water supply at 10 °C and a maximum temperature setting, see the diagram.
Steel, enamelled Thermal insulation material Casing material Colour White White White White Connections Water connection G 1/2 A G 1/2 A G 1/2 A G 1/2 A Dimensions Depth Height Width Weights Weight | SHC 10 | SHC 15 www.stiebel-eltron.com...