Operating Instructions For Sb; Unit Description; Important Instruction; Care And Maintenance - STIEBEL ELTRON SB 302 S Operating And Installation Instructions

Unvented (pressurized) floorstanding combi-water heaters
Hide thumbs Also See for SB 302 S:
Table of Contents

Advertisement

Available languages

Available languages

1. Operating instructions for SB . . .
1.1 Unit description
The Stiebel Eltron SB 302 S, SB 402 S,
SB 602 AC, SB 1002 AC and SB 650/3 AC
floor-standing combi-water heaters are
combi- heaters for universal use. They are
supplied without fittings and are fitted with
suitable heat exchangers, heating elements,
blind flanges, or screw-in heating elements
by customers, according to requirements (see
Table 2).
Operating guidance is to be taken from the
appropriate operating and installation instruc-
tions.
1.2 Important instruction
• The water storage heater is under
mains water pressure.
• During heating up, water will drip out of
the safety valve.
If water continues to drip out of the safety
valve after heating up has been completed,
the device must be switched off and depres-
surized, and a qualified installer called.
• The blow-out line of the safety valve must
not be closed.
• With temperature settings of greater than
45 °C, water at high temperature may start
flowing immediately.
• If it is intended that children or persons
with restricted physical, sensory, or mental
capacity should operate the appliance, it
must be ensured that this is only done after
appropriate instruction has been provided by
the person responsible for their safety.
Children should be supervised to ensure that
they do not play with the device - risk of
scalding!
• Have the floor-standing combi-water
heater, the safety group, and the built-in
special accessory components regularly
checked by a qualified installer.
• The steel cylinder is fitted internally with a
special enamel coating to protect it against
corrosion, and also has a protective anode.
– In the case of types SB 302-402 S and SB
602-1002 AC, the protective anode has a wear
display (display element). Once the signal
anode has worn away, moisture reaches the
display element A (3), causing it to change
colour.
If the display element turns red,
please inform your qualified installer
so that he can check the signal anode and
replace it if necessary.
Anode o. k.
Service
white
1
for the user and the qualified installer
– In the case of the SB 650/3 AC, the protec-
tive anode must be checked for the first time
after two years, and if necessary replaced.
The qualified installer, who knows the quality
of the water locally, will tell you when the
next maintenance needs to be carried out.
1.3 Care and maintenance
Maintenance work, such as checking
the electrical safety, may only be car-
ried out by a qualified installer.
• At high temperatures almost all water pre-
cipitates limescale. This forms deposits in
the appliance and affects its function and
service life. The heating elements must
accordingly have the limescale removed
from time to time.
The qualified installer, who is familiar with
the quality of the local water, will advise
you of the time for the next maintenance
inspection.
• A damp cloth is sufficient for caring for the
plastic components. Do not use any abra-
sive or scouring cleaning agents.
1.5 Technical data
(the data on the floor-standing water heater rating plate are applicable)
Type
Capacity
Permissible operating
pressure
Test pressure
(empty cylinder)
Weight
Flange openings
Hot water temperature
Dimensions mm
red
Table 1
1) The floor-standing combi-water heaters are designed for the storage of hot water up to a
temperature of 110 °C.
2) Dimensions of special accessory „heat insulation WD 602, WD 1002, WD 650"
3) Max. possible immersion depth of the special accessory components
A
SB 302 S
SB 402 S
l
300
400
MPa (bar) 1 (10)
1 (10)
MPa (bar) 1,5 (15)
1,5 (15)
kg 101
119
Stck.
2
2
1)
max. °C 110
110
a 550
600
b 700
750
c 360
375
d 350
350
e 1025
1145
f 1040
1160
2)
-
-
g
h 1585
1755
l 390
410
3)
530
580
k
m 75
75
n 55
55
p -
-
r -
-
s -
-
Hole circle-Ø o 490
540
1.4 Instructions for installation
and use
Keep these instructions in a safe
place, and give them to the next user
in the event of a change of ownership. In
the event of any maintenance or repair work
being required, provide them to the quali-
fied installer for his reference.
SB 602 AC
SB 1002 AC SB 650/3 AC
600
1000
1 (10)
1 (10)
1,5
(15)
1,5 (15)
154
212
2
2
110
110
750
750
950
950
530
530
350
350
1150
1790
1200
1840
1800
2640
1685
2525
-
-
790
790
-
-
115
115
-
-
-
-
-
-
690
690
650
1 (10)
1,5 (15)
190
3
110
750
950
450
515
1480
-
1850
1725
-
790
125
-
1135
560
1305
690

Advertisement

Table of Contents
loading