Weekly Maintenance - Data I/O FLX500 Maintaining

Flash programming handler
Table of Contents

Advertisement

2 ... Periodic Maintenance  Weekly Maintenance
ated by pushing the Socket Actuator button on
the monitor.
CAUTION:
ator Plate lowers onto the sockets to open
them. Keep fingers and objects away from the
Socket Adapters when actuating them.
Check the sockets for wear; replace the Socket
Adapter if necessary.
If further cleaning is needed for best throughput,
remove the Socket Adapter and clean it in an
ultrasonic bath with approved cleaning fluid.
Isopropyl alcohol (isopropanol) can be used to
clean the Socket Adapter.

Weekly Maintenance

Running the Self-test
Checking Probe Tips
Cleaning the Fiducials and Sensors
Running the Self-test
Tools Required:
• Vacuum tweezers
Perform the system Self-test once each week to
verify proper operation of all internal electronic
systems.
NOTE: The Self-test runs automatically
when power is applied to the
To run the Self-test:
1.
End a job if one is running.
Pinch Point. The Actu-