Outgoing High-Layer-Compatibility can be controlled by setting the
value of S-register S(108+n) as follows:
n=0 - (S108) Setting for analog adapter 2 (omni.net).
n=2 - (S110) Setting for ISDN data calls.
n=3 - (S111) Setting for analog adapter 1 (non-data).
S(108+n=)
0
1
4
40
49
50
53
56
65
Example: ATS111=4 sets Fax compatibility message for Analog
Port 1.
Bearer-Capability and Low-Layer-Compatibility information
elements will be determined when you configure the B channel
protocols using the command ATBnn. The outgoing Low-Layer-
Compatibility information element can be turned on or off by setting
S80 bit 'n' as follows:
n = 4 for the analog adapter 2 (omni.net).
n = 6 for ISDN data calls.
n = 7 for the analog adapter 1 (non-data).
S108.n= Function
S80.n=0
Disable outgoing Low-Layer-Compatibility (default).
S80.n=1
Enable outgoing Low-Layer-Compatibility.
80 Advanced ISDN Call Control
Function
No High-Layer-Compatibility info element will be
sent (default).
Telephony.
Facsimile Group 2/3.
Teletex service (Rec. F.220).
Teletex service (Rec. F.200).
International interworking for video services (Rec.
F.300 and T.110).
Telex service (Rec. F.60).
Message Handling Systems (MHS) (Rec. X.400
series).
OSI application (Rec. X.200 series).