Degrease the piston rod.
–
Clamp the piston rod with the special tool.
Clamping stand (T14016S) (
B04528-10
–
Remove nut
–
Completely remove shim stack
B04529-10
–
Remove piston
–
Completely remove shim stack
B04530-10
–
Remove spring
–
Warm up the piston rod in area
Guideline
50 °C (122 °F)
–
Remove tap rebound
B04531-10
–
Remove spring
–
Remove valve
–
Unclamp the piston rod.
B04539-10
FORK, TRIPLE CLAMP 6
p. 374)
6
.
7
.
8
.
9
.
bk
.
A
.
bl
.
bm
.
bn
of the rebound damping with the spring.
47