Pilz PITmode flex visu Manual

Pilz PITmode flex visu Manual

Control and signal devices

Advertisement

Quick Links

PITmode flex visu
}
Control and signal devices
System Description-1005364-EN-01

Advertisement

Table of Contents
loading

Summary of Contents for Pilz PITmode flex visu

  • Page 1 PITmode flex visu Control and signal devices System Description-1005364-EN-01...
  • Page 2 Preface This document is the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for the user's internal purposes. Suggestions and comments for improving this documenta- tion will be gratefully received.
  • Page 3: Table Of Contents

    Select safe mode of operation MSO1 ... MSO8................ 5.5.2 Button status indicators ......................5.5.3 Status and error messages through the PNOZmulti..............Examples for PITmode flex visu with PNOZ m B1 ..............5.6.1 Example 1 ..........................5.6.2 Example 2 ..........................5.6.3 Example 3 ..........................
  • Page 4 Contents Calculating the safety-related characteristic data .............. System Description PITmode flex visu 1005364-EN-01...
  • Page 5: Introduction

    It also highlights areas within the text that are of particular import- ance. INFORMATION This gives advice on applications and provides information on special fea- tures. System Description PITmode flex visu 1005364-EN-01...
  • Page 6: Overview Of Systems For Safety-Related Operating Mode Selection

    PIT m4SEU Fig.: Overview of systems for safety-related operating mode selection PITmode fusion, PITmode flex and PITmode flex visu are systems for the safety-related se- lection of modes of safe operation (MSO). For example these include operating modes such as automatic, setting, test run, process monitoring and service. In all systems, access restrictions are guaranteed by the authentication system PITreader.
  • Page 7 Overview of systems for safety-related operating mode selection – Elements/components from Pilz The chapters that follow describe the system PITmode flex visu. There are separate docu- ments for the other systems. System Description PITmode flex visu 1005364-EN-01...
  • Page 8: Safety

    Safety Intended use PITmode flex visu is a system for the safety-related selection of modes of safe operation (MSO). For example these include operating modes such as automatic, setting, test run, process monitoring and service. Up to 8 modes of safe operation can be selected on PIT- mode flex visu.
  • Page 9: Warranty And Liability

    When decommissioning, please comply with local regulations regarding the disposal of electronic devices (e.g. Electrical and Electronic Equipment Act). Application conditions NOTICE With safety-related operating mode selection, only the Pilz display units lis- ted in the section entitled Intended use [ may be used for visualisation.
  • Page 10 Please note also: The user must provide evidence of the achieved/required PL in accordance with EN ISO 13849. The PASvisu Server must be on the display unit and not on an external device. System Description PITmode flex visu | 10 1005364-EN-01...
  • Page 11 If you need more than 10 working areas, the connected Modbus/TCP network must be segmented (e.g. using firewalls). You will need to ensure that the PASvisu visualisation project corresponds to that of the PNOZmulti project. Changes must be made on both sides. System Description PITmode flex visu | 11 1005364-EN-01...
  • Page 12: Security

    The products’ communication interfaces should be protected against physical manipula- tion. Protect the 24 V inputs and outputs on the safety controller against physical manipulation through protected wiring, e.g. by installing the safety controller in a lockable control cab- inet. System Description PITmode flex visu | 12 1005364-EN-01...
  • Page 13: Pitmode Flex Visu With Pnozmulti

    MSO outputs technology PITmode flex visu is a system for the safety-related selection of modes of safe operation (MSO). For example these include operating modes such as automatic, setting, test run, process monitoring and service. Up to 8 modes of safe operation can be selected on PIT- mode flex visu.
  • Page 14: Safety Features

    PITmode flex visu with PNOZmulti Selection device Operating modes are selected using a Visu display unit (Visu panel). Only the display units stated in the section entitled Intended use may be used for safety- related operating mode selection. A project from the visualisation system PASvisu is operated on the display unit.
  • Page 15: Working Areas

    PITmode flex visu with PNOZmulti 5.1.3 Working areas A plant can be divided into different working areas. Working areas may be “infeed”, "ma- chining” and “outfeed” for example. Separate operating modes may be assigned to each working area. In the PNOZmulti Configurator, one working area is assigned to each MSO flex visu ele- ment.
  • Page 16: Acknowledge

    PITmode flex visu with PNOZmulti 5.1.5 Acknowledge As an option, an input can be configured to confirm the operating mode selection via the controller. The selected operating mode is adopted only when confirmation has been received via the PNOZmulti input that is configured for the acknowledgement.
  • Page 17: Installation

    PITmode flex visu with PNOZmulti Installation 5.3.1 Connect PITreader The PITreader is connected to the base unit PNOZ m B1 via an Ethernet cable (for the number of PITreaders that can be connected see System expansion [ 16]). Please refer to the information and requirements in the operating manual for the PITreader.
  • Page 18 PITmode flex visu with PNOZmulti MSO8 = Service 4 The labels on the buttons and icons can be changed. You can configure which buttons you use. The buttons for the service modes are only visible on the display unit if a transponder key with permission for the service modes is inserted and the selection lock is not activated.
  • Page 19: Configure Pitreader

    PITmode flex visu with PNOZmulti 5.4.2 Configure PITreader The PITreader is configured using a web application, see PITreader operating manual. 5.4.3 Configure PNOZmulti 5.4.3.1 Configure hardware Add the following devices to the hardware configuration: Base unit PNOZ m B1 Input and output modules...
  • Page 20: Configure Safety Function

    PITmode flex visu with PNOZmulti 5.4.3.5 Configure safety function The actual activation of the safety functions required for the selected operating mode may depend on the application (e.g. light curtain or safety gates). Assign the safety functions required for the various modes of safe operation using outputs MSO1 ...
  • Page 21 PITmode flex visu with PNOZmulti 2. Confirm operating mode selection Press the “Confirm preselection” button on the tile. The button flashes green. The preselection is now confirmed, but not yet acknowledged by the PNOZmulti. If "Acknowledge" is configured, the mode of safe operation will not be adopted until the selection is acknowledged (1-signal at "Acknowledge”...
  • Page 22: Button Status Indicators

    PITmode flex visu with PNOZmulti 5.5.2 Button status indicators A tile in PASvisu contains a maximum of 8 buttons for selecting operating modes. Each but- ton has triangles on the bottom left and top right to indicate the status. Status indicator...
  • Page 23: Status And Error Messages Through The Pnozmulti

    PITmode flex visu with PNOZmulti 5.5.3 Status and error messages through the PNOZmulti The status of the operating modes can be displayed using a logic link to the MSO outputs or via the diagnostic words. 2 diagnostic words are available for the MSO flex visu element. These can be displayed via a display unit.
  • Page 24 PITmode flex visu with PNOZmulti Bit No. Description Cause and remedy Incorrect user entry Possible causes: Lock input is active More than one button was operated simul- taneously Note: Prior to a new selection and to reset the diagnostic message, no button may be operated.
  • Page 25 PITmode flex visu with PNOZmulti Bit No. Description Cause and remedy Communication with the PITreader is interrupted Possible causes: Cable connection broken between PNOZmulti and PITreader IP address is configured incorrectly Remedy: Check the connection between the PITreader and the PNOZmulti.
  • Page 26: Examples For Pitmode Flex Visu With Pnoz M B1

    PITmode flex visu with PNOZmulti Examples for PITmode flex visu with PNOZ m B1 5.6.1 Example 1 1 PITreader for 1 working area (WA) and display on a Visu display unit. WA 1 5.6.2 Example 2 4 PITreaders, 1 for each working area (WA). Each working area has its own display on a Visu display unit.
  • Page 27: Example 3

    PITmode flex visu with PNOZmulti 5.6.3 Example 3 2 PITreaders, each covering 2 working areas (WA). 2 working areas covered by one dis- play on a Visu display unit. WA 1 WA 2 WA 3 WA 4 System Description PITmode flex visu...
  • Page 28 A safety function's SIL/PL values are not identical to the SIL/PL values of the units that are used and may be different. We recommend that you use the PAScal software tool to calculate the safety function's SIL/PL values. System Description PITmode flex visu | 28 1005364-EN-01...
  • Page 29 We are represented internationally. Please refer to our homepage www.pilz.com for further details or contact our headquarters. Headquarters: Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.com, Internet: www.pilz.com...

This manual is also suitable for:

Pitmode fusionPitmode flex

Table of Contents