(1) Manual Sampling

This section explains how to use the [RECORD] key to manually specify the start and end point of the
sampling process. Manual sampling is convenient for example for quickly sampling a desired rhythm or bass
pattern while listening to a CD.
Except for special cases such as personal use, unauthorized sampling of material from copyrighted sources
(including but not limited to CDs, records, tapes, video clips, broadcast material) is prohibited.
• In the factory default condition, the ST-224 will read the preset sample sources from
backup memory into the main memory. Also in this condition, it is possible to sample a new
NOTE
source and store the result in a free area of the main memory, but for maximum recording
length, you should first erase some or all preset samples from the main memory (
• The sampled waveform is temporarily stored in the main memory, but it will be lost if the unit
is turned off without first transferring the waveform data to the internal backup memory or
external data cards. (The next time the unit is turned on, the contents of the backup
memory will be read into the main memory.) Be sure to store important sample data (
TIME STRETCH
VOLUME/BASS
SCRATCH
EXCITER
DELAY
TREMOLO
REVERB
FLANGER
STEP CRY
CHORUS
PHASER
PITCH SHIFTER
LOW-PASS
DIMENSION
HIGH-PASS
DISTORTION
RING MODULATOR
EDIT 2
A
B
PAD ENABLE
EFFECT SYNC
EDIT 1
Connect the sound source (CD player or microphone etc.) to the [INPUT R] and [INPUT
1
STEP
L/MONO] jacks (
2
STEP
Press the [RECORD] key.
The ST-224 goes into the sampling standby mode, and the LED of
the [RECORD] key flashes. A number for the new sample is shown on
the display.
3
When wishing to change the sampling grade (sound quality), press the [GRADE] key.
STEP
The currently selected grade appears on the display. You can change
the grade between three settings by holding down the [GRADE] key
and using the [-] and [+] keys.
Grade
HiFi
(High fidelity)
Stnd
(Standard)
LoFi
(Low fidelity)
20

Let's Try Out Sampling

BPM/VALUE
SONG
AUTO PAN
REC
PLAY/STOP
LO-FI EFFECT
COMPRESSOR
EXTREME EQ
RESONANCE
PLAYLIST
MEASURE
EFFECT
TAP
COPY
DELETE
BPM
ON/OFF
BACKUP
EXIT
LOAD
SAVE
AUTO SYNC
4
OFFSET
SHIFT
LOOP/MARK
p. 8 –
9).
Sampling
Maximum sampling time
frequency
(per sample)
32kHz
30 seconds
16kHz
60 seconds
8kHz
120 seconds
SAMPLING
MONO
GRADE
RE-SAMPLE
STEREO
BEAT
SAMPLE/SONG
RECORD
PLAY/STOP
+
PAD ASSIGN CAPACITY
ERASE
OPTIMIZE
INTERNAL/DATA CARD
SPECIAL
FUNCTION
PAD
SONG
BANK
BANK
BANK
BPM/VALUE
MEASURE
BEAT
SAMPLE/SONG
Sampling time
(total)
Mono 60 seconds/Stereo 30 seconds
Mono 120 seconds/Stereo 60 seconds
Mono 240 seconds/Stereo 120 seconds
p.
36).
p.
59).
1
2
3
RECORD
Sample number
GRADE