Zoom Sampletrak ST-224 Operation Manual page 39

Zoom sampletrak operation manual st-224
Table of Contents

Advertisement

5
STEP
Press the [AUTO SYNC] key.
The [AUTO SYNC] LED flashes, and the indication "MAStEr" (master)
appears on the display. This guides the user to specify the pad to be
used as reference (master).
Use the [BANK 1] - [BANK 3] keys and the pads 1 - 8 to select the master pad for auto
6
STEP
sync.
The LED of the selected pad lights up.
7
STEP
Press the [AUTO SYNC] key.
The indication "SLAvE" (slave) appears on the display. This guides
the user to specify the pad to be used as slave pad whose tempo is
to be changed.
Use the [BANK 1] - [BANK 3] keys and the pads 1 - 8 to select the slave pad for auto
8
STEP
sync.
The LED of the selected pad lights up.
• When "rESMPL" is selected in step 4, a new sample will be
NOTE
created in the main memory. Therefore, sufficient free memory
must be available. If not, or if the maximum number of 32
samples has already been reached, the indication "FULL"
appears on the display when the slave pad is specified in step 8.
In this case, delete unnecessary samples first.
• A pad which has same BPM value as the master pad can not be
selected, in this case the indication "SAME" appears on the
display.
9
STEP
Press the [AUTO SYNC] key.
• When "tuninG" is selected in step 4
The tuning value of the slave pad is changed.
• If "rESMPL" is selected in step 4
The length of the sample assigned to the slave pad is changed, a
new sample is created in the main memory (resampling) and
assigned to the slave pad. During recording, the new sample can
be monitored via the output jacks.
SAMPLE #1
(MASTER)
BPM/VALUE
MEASURE
RESAMPLING
SAMPLE #2
SAMPLE #3
(SLAVE)
BEAT
SAMPLE/SONG
BANK 1– 3 keys
1
BANK
BANK 1– 3 keys
1
BANK
SAMPLE #4
AUTO SYNC
Pads 1 – 8
AUTO SYNC
Pads 1 – 8
AUTO SYNC
39