Pro Mach Orion SENTRY System Manual page 49

Table of Contents

Advertisement

Orion
Revision 2.8
27 August 2014
CAUTION
Note:
This procedure should only be performed by qualified service personnel.
1. Raise carriage to chest height.
2. Disconnect power from the machine.
3. Remove the film from the carriage.
4. Open the threading gate.
5. With the brush wet with rubbing alcohol, lightly scrub both rubber rollers while rotat-
ing them. The goal is to just get any debris out of the rollers.
Rubbing alcohol is recommended because it is light enough to pen-
etrate the rubber and it evaporates quickly.
6. After the entire rollers' surface has been cleaned, apply compressed air to the rollers to
dry quickly.
7. Re-apply power.
8. Re-load film as discussed earlier.
Semi-Automatic Stretch Wrapping Machine