5.

Maintenance

Maintenance

Motor Maintenance

Reducer Oil Change

Note:
All general information about machine maintenance is based on normal machine working
conditions: indoor, moderate dust and low moisture environment, and maximum rotation
of 9 RPM. They should be regarded as guidelines, reviewed and corrected according to
requirements of actual use and conditions.
The drive motors require little maintenance. Simply blow out debris with compressed air
on a regular basis.
All external cap screws and plugs on the reducing transmission should be checked for
tightness after the first week. It is recommended to change the oil every six months or at
least 1800 hours of operation, whichever comes first. When adding or changing oil, the
transmission should never be filled above the oil level mark indicated, because leakage
and overheating may occur. Below is the list of the type of lubricant that should be used.
List of recommended reducer oils:
Table 5-1. Recommended Reducer Lubricants
MANUFACTURER
American Oil Co.
Cities Service Oil Co.
Gulf Oil Corp.
Mobil Oil Corp.
Philips Oil Corp.
Texaco Inc.
Shell Oil Co.
Union Oil of Cal.
For most applications, Mobil One Synthetic 75/90 gear lube is a pre-
ferred lubricant.
Semi-Automatic Stretch Wrapping Machine
LUBRICANT
American Cyl Oil no: 196-L
Citgo Cyl Oil 100-5
Gulf Senate 155
Mobil 600 W Suer-r Cyl. Oil
Andes S 180
624 + 650T Cyl.Oil
Velvata Oil J82
Red Line Worm Gear Lube 140
Sentry by Orion
Maintenance
Page 5-1