Applicable Crimping Terminals
• (Refer to the Crimping Terminal 1 or 2 shown in the drawing below.)
• HS1C
Terminals No. 1 to 6: Use solid or stranded wires only (crimping ter-
minals not applicable).
Terminals No. 7 and 8: Crimping Terminal 1
Ground Terminal:
Crimping Terminal 2
• HS1B
Ground Terminal: Crimping Terminal 2
Other Terminals: Crimping Terminal 1
HS2B, HS5B, and HS1E
Crimping Terminal 1
3.6 min.
3.5 max.
L1 ( mm )
ø3.6 min.
Crimping Terminal 1
Use an insulation tube on the crimping terminal.
Wire
Approx. 4mm
Insulation Tube
Installation Examples (see the diagrams below)
Mounting on Sliding Doors
HS9Z-A1 Actuator
Door Stop
Mounting on Hinged Doors
HS9Z-A2 Actuator
www.idec.com
Operation Precautions
3.8 max.
3.5 min.
L1 ( mm )
ø4.1 min.
Crimping Terminal 2
Crimping Terminal
Door
Latch
HS9Z-A1 Actuator
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
Applicable Connectors (As shown below)
• Use connectors which maintain the IP67 protection.
• Applicable Connector Dimensions
• Flex Conduit: VF03 (Japan Flex) www.nipolex.co.jp
• Steel Connector (G1/2): ALC-103
(PF13.5): RBC-103PG13.5
G1/2 or PG13.5
9 mm max.
Recommended Screw Tightening Torque
• HS1C: 5.0±0.5 N-m (approx. 50±5 kgf-cm)
(4 or 6 pcs of M5 hex socket head cap screws)
• HS1B: 5.0±0.5 N-m (approx. 50±5 kgf-cm)
(2 or 4 pcs. of M5 hex socket head cap screws)
• HS2B: 5.0±0.5 N-m (approx. 50±5 kgf-cm)
(2 pcs of M5 hex socket head cap screws)
• HS5B: 4.0±0.4 N-m (approx. 40±4 kgf-cm)
(2 pcs of M4 hex socket head cap screws)
• HS1E: 5.0±0.5 N-m (approx. 50±5 kgf-cm)
(4 or 6 pcs of M5 hex socket head cap screws)
• Key (HS9Z-A1/A2)
5.0±0.5 N-m (approx. 50±5 kgf·cm)
• (2 pcs. of M6 hex socket head cap screws)
Key (HS9Z-A51/A52)
• 2.0±0.2 N-m (approx. 20±2 kgf·cm)
(2 pcs of M4 hex socket head cap screws)
• 1.0±0.2 N-m (approx. 10±2 kgf·cm)
(2 pcs of M4 Phillips screws)
The screws are supplied by the user.
Applicable Wire Size
• HS1C: 0.5 to 0.75 mm2 (Terminals No.1, 2, 5 to 8)
1.0 to 1.25 mm2 (Terminals No.3, 4, and
grounding terminal)
• HS5B: 0.5 to 1.25 mm2
• HS1E: 0.5 to 1.25 mm2
Precautions