BYD Energy Pod Series User's Installation And Use Manual page 12

Table of Contents

Advertisement

Working
Discharge
State
Match
Power
BYD
load
supply
Energy Pod
source
PV
/
The priority of power supply to load is as:
① Photovoltaic power supply > ② BYD Energy Pod power supply > ③ Grid power
supply
5.2 Remote control
The product is provided with the RS485 interface and capable of responding to the
control command issued by the external controller. Please refer to the technical
agreement for details of external protocol, charge and discharge control, standby and
shutdown control, etc.
Note: The remote control function shall be used when the power grid is
connected.
5.3 Emergency power supply
In case of the grid-connected operation of the system, when the power grid blackout
occurs, the Energy Pod can supply emergency power for the specific loads
(lighting, mobile phone charging), the grid-connected switch to emergency power
supply is carried out automatically, with a switch time of less than 1S; when the power
grid returns to normal, the system is automatically switching to the state of grid-
connected operation. The emergency power supply load shall be connected to the
Load interface.
Discharge
Charge
Grid &
PV
PV
Load
Load & BYD Energy Pod
Secret
Discharge
Discharge
BYD
BYD Energy
Energy Pod
Pod
& PV
Load
/
10

Hide quick links: