Solartouch Controller Menus (Main Menu - Advanced Menu); Heating; Solar Hold Feature - Pentair SOLARTOUCH 521592 Installation And User Manual

Solar controller for pool and spa
Table of Contents

Advertisement

SolarTouch
Main Menus
Use the Main Menu for everyday solar operating features and the Advanced Menu for
solar utility settings. To access the Main Menu, press the MENU button. The Main Menu
items are as follows:
Main Menu
Heating Menu
Cooling Menu
Advanced Menu
To access the Advanced Menu, press and hold (three seconds) and release the MENU
button. The Advanced Menu items are as follows:
Advanced Menu

Heating

(see page 5)
Utility
(see page 10)
Manual Mode
(see page 9)
Freeze Control
(see page 8)
Cooling
(see page 7)
Heating
The SolarTouch controller can heat the pool or spa by circulating water through the
solar panels. Heating must be ENABLED in the Heating Menu. The initial factory default
setting is "Enabled." The Start and Stop temperature differentials for solar water heating
are adjustable. Factory temperature differential settings are: Start (default 6°) and Stop
(default 3°). The Heating Menu settings are as follows:
Menu Item
Enable/Disable
Target Temp
Diff To Start * (4°F - 9°F)
Diff To Stop * (2°F - 5°F)
(*) available in Advanced Menu
Controller Menus
®
Enable/Disable: [Enable/Disable]
Target Temp - 40° F - 104° F (4° C - 40° C)
Set temperature higher or equal to Cooling Target Temp
Enable/Disable: [Enable/Disable]
Target Temp - 40° F - 104° F (4° C - 40° C
Set temperature lower or equal to Heating Target Temp
Enable/Disable: [Enable (Default)]
Diff To Stop: 3F (2-5F) - Diff To Start: 6F (4F-9F)
Target Temp - 40° F - 104° F (4° C - 40° C)
Temp Units: [FAHRENHEIT / CELSIUS] - Erase EEPROM [No/Yes]
Calibrate Water: Adjust +/- 10 deg. - Calibrate Solar: Adjust +/- 10° deg.
Solar Override - Enable/Disable (Default) - Only used for IntelliFlo pump (see page 12).
Solar Boost Pump: [Off/On]
No IntelliFlo: (No IntelliFlo
IntelliFlo: (Displays when IntelliFlo
SolarTouch
Control System. Ext. Ctrl. Programs are set at the pump.
®
Ext. Ctrl. Program 2: Assigned for solar heating/cooling (see page 5-7).
Ext. Ctrl. Program 3: Assigned for freeze protect (see page 8).
Ext. Ctrl. Program 4: Assigned for Solar Hold (see page 6-8).
Actuator: [Off/On] Cleaner Pump: [Off/On] (see page 8).
Enable/Disable: [Disable (Default)]
Enable/Disable: [Disable (Default)]
Diff To Stop: 3F (2F-5F) - Diff To Start: 6F (4F-9F)
Target Temp - 40° F - 104° F (4° C - 40° C)
Action
Enables or disables Heating.
The desired pool/spa temperature.
The minimum temperature difference to start Heating.
The temperature difference at which Heating will stop.
SolarTouch
Pump installed or no communication from pump
®
®
Pump if connected and communicating with
Solar Control System Installation and User's Guide
®
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Solartouch 521632Solartouch 521942