Pentair Biffi ICON 2000 Instructions And Operating Manual

Pentair Biffi ICON 2000 Instructions And Operating Manual

Electric actuators
Table of Contents

Advertisement

Biffi ICON 2000
InstructIon and operatIng manual
General instructions for installation
Maintenance and trouBleshootinG
www.pentair.com/valves
operation and confiGuration
spare parts and drawinGs
© 2012 Pentair plc� All rights reserved�
index
1
General safety instructions ������������������� 2
1�1
Range of application �������������������������������� 2
1�2
Safety instructions for installation in
hazardous area ���������������������������������������� 2
1�3
1�4
Terms and conditions ������������������������������ 3
2
storage and pre-installation ����������������� 4
2�1
2�2
Storage procedure ����������������������������������� 4
2�3
installation ������������������������������������������������ 5
3
installation ���������������������������������������������� 5
3�1
Working condition ������������������������������������ 5
3�2
the actuator ���������������������������������������������� 5
3�3
Manual operation ������������������������������������� 8
3�4
3�5
Electrical connections ��������������������������� 10
3�6
enclosure������������������������������������������������ 10
3�7
Cable entries ������������������������������������������ 10
3�8
Terminal board �������������������������������������� 11
3�9
enclosures ���������������������������������������������� 11
3�10
explosive dusts ��������������������������������������� 12
4
lubrication �������������������������������������������� 12
4�1
Lubrication inspection ��������������������������� 12
5
operating the icon 2000���������������������� 13
5�1
Operation by handwheel ������������������������ 13
5�2
Electrical operation ������������������������������� 13
5�3
Local control ������������������������������������������ 13
5�4
Local indication �������������������������������������� 13
5�5
Lock of the 3-position selector ������������� 14
5�6
Remote control �������������������������������������� 14
5�7
5�8
Optional modules ����������������������������������� 16
5�9
Base card of the ICON 2000 v4 ������������� 18
VcioM-01232-en 16/01

Advertisement

Table of Contents
loading

Summary of Contents for Pentair Biffi ICON 2000

  • Page 1: Table Of Contents

    Remote control �������������������������������������� 14 5�7 Operating the ICON 2000 for the first time ������������������������������������������������� 16 5�8 Optional modules ����������������������������������� 16 5�9 Base card of the ICON 2000 v4 ������������� 18 www.pentair.com/valves VcioM-01232-en 16/01 © 2012 Pentair plc� All rights reserved�...
  • Page 2: General Safety Instructions

    Biffi ICON 2000 InstructIon and operatIng manual 1� GENERAL SAfETy local controls���������������������������������������� 19 Actuators have IP66/68 degree of protection 6�1 Description of the local operator according to EN 60529� INSTRuCTIONS interface ������������������������������������������������� 19 1.2.1 Marking 6�2 Configuration options ���������������������������� 22 1.1 ranGe of application...
  • Page 3: Applicable Standards And Regulations

    Biffi ICON 2000 InstructIon and operatIng manual 1.4 terMs and conditions hazardous zone zone categories according to 94/9/ec directive Gas, mist or vapors Biffi guarantees each single product to be free Gas, mists or vapors 2G or 1G from defects and to conform to current goods...
  • Page 4: Storage And Pre-Installation

    Biffi ICON 2000 InstructIon and operatIng manual 2� STORAGE AND 2.2.2 storage for a brief period (less than one year) PRE-INSTALLATION 2.2.2.1 indoor storage 2.1 tests to Be carried out when the • Make sure that the actuators are kept in a dry actuator is receiVed place, laid on a wooden pallet and protected from dust�...
  • Page 5: Checks To Be Performed Before

    Biffi ICON 2000 InstructIon and operatIng manual 3� INSTALLATION 3.1 workinG condition The standard actuators are suitable for the following environment temperatures: -30°C +85°C (-22°f to +185°f) Special versions are available for extreme environment temperatures: -40°C +70°C (-40°f to +158°f) -55°C +70°C (-67°f to +158°f)
  • Page 6 Biffi ICON 2000 InstructIon and operatIng manual 3.2.1 type “a” coupling block 3.2.1.1 preparing the bushing With a compass key, unscrew the lower ring nut� Extract the stem nut from the block housing� The internal thrust bearing will remain at the bottom of the block housing�...
  • Page 7 Biffi ICON 2000 InstructIon and operatIng manual 3.2.2 type “B1” and “B2” coupling blocks 3.2.2.1 preparing the bushing With a compass key, unscrew the lower ring nut� Extract the bushing from the block housing� The internal thrust washer will remain at the bottom of the block housing�...
  • Page 8: Manual Operation

    Biffi ICON 2000 InstructIon and operatIng manual 3.2.3 type “B3” and “B4” coupling blocks 3.2.3.2 re-assembling the internal parts 3.2.3.1 preparing the bushing It is advisable to wash the dismantled Remove the fixing screws of the coupling parts with a suitable solvent; dry them with flange�...
  • Page 9: Mounting The Actuator Onto The Valve

    Biffi ICON 2000 InstructIon and operatIng manual size Max. weight (dn) (kg) warninG Never lift the valve/actuator assembly without securing slings to both the valve and the actuator. warninG Never use the handwheel to lift the actuator. 3.4 MountinG the actuator onto the...
  • Page 10: Electrical Connections

    Biffi ICON 2000 InstructIon and operatIng manual 3.5 electrical connections 3.7 caBle entries Before powering the actuator check that the The sealing of cables and conduit entries supply voltage details on the nameplate are should be carried out in accordance with correct for the plant�...
  • Page 11: Terminal Board

    Biffi ICON 2000 InstructIon and operatIng manual on the back of the terminals enclosure cover, So please: to ensure a correct electrical connection� All • Do not damage the explosionproof mating terminations should be made by insulated ring surfaces on the housing and on the electrical or spade connectors using the appropriate enclosures covers�...
  • Page 12: Installation In Environment With

    Biffi ICON 2000 InstructIon and operatIng manual 3.10 installation in enVironMent with explosiVe dusts iMportant Electric actuator ICON 2000 shall be installed and maintained; according to the applicable rules regarding the electrical installations in hazardous area (other than mines) classified as zone 21 (dust);...
  • Page 13: Operating The Icon 2000

    Biffi ICON 2000 InstructIon and operatIng manual 5� OPERATING THE ICON 2000 According to the position of the local selector, the OPEN/yES and CLOSE/NO push-buttons 5.1 operation By handwheel work as follows: - Open/Close commands if the selector is in To operate the actuator by handwheel, press Local position�...
  • Page 14: Lock Of The 3-Position Selector

    Biffi ICON 2000 InstructIon and operatIng manual 3 wires (see the remote connections diagram option a1) shown beside) With option “3 wires” (OPEN, CLOSE, COMMON), the actuator can be driven in either “push-to-run” or “latched with instant reverse” mode� option B1) In “push-to-run”...
  • Page 15 Biffi ICON 2000 InstructIon and operatIng manual option d1) 5.6.2 output contacts 5.6.3 esd operation An ESD (Emergency Shut Down) signal Standard version - Monitor relay: on the terminal board, the can be sent to the actuator to override any...
  • Page 16: Operating The Icon 2000 For The First Time

    Biffi ICON 2000 InstructIon and operatIng manual 5.7 operatinG the icon 2000 for the Set torque limits, position limits and close first tiMe direction by means of the “stroke limits routine” of the “actuator set-up” menu (see chapter 9)� Before attempting to operate the ICON 2000...
  • Page 17 Biffi ICON 2000 InstructIon and operatIng manual actiVe loop Actuator terminals External power supply • 4-20 ma analog output The 4-20 mA output can be configured to 20-30 provide a signal proportional to either “position” Cable V DC or “torque”� The polarity option allows to...
  • Page 18: Base Card Of The Icon 2000 V4

    Biffi ICON 2000 InstructIon and operatIng manual 5.9 Base card of the icon 2000 V4 ain/aout card This optional card is used in place of the Terminal Board Adaptor (TBA) card when an analog 4-20 mA input and output signal is requested�...
  • Page 19: Description Of The Local Operator

    Biffi ICON 2000 InstructIon and operatIng manual 6� LOCAL CONTROLS - actuator control - actuator configuration 6.1 description of the local operator - actuator status visualisation interface The figures on the following pages describe the function of each component of the local operator interface�...
  • Page 20 Biffi ICON 2000 InstructIon and operatIng manual description of VariaBles and reports torque output torque in % of the nominal torque stated in the NAMEPLATE menu motor speed RPM of electrical motor main voltage voltage (V) and frequency (Hz) of mains current current (A) absorbed by the motor temperature temperature (°C), inside the electronic compartment...
  • Page 21 Biffi ICON 2000 InstructIon and operatIng manual The following drawing shows the use of the OPEN / yES, CLOSE / NO and STOP push-buttons in function of the local selector position� local reMote 3-position selector = OPEN/yES push-button = CLOSE/NO push-button...
  • Page 22: 6�2 Configuration Options

    Biffi ICON 2000 InstructIon and operatIng manual 6.2 confiGuration options nameplate The parameters appear on the alphanumeric display in the same order both in view and This menu includes a series of data identifying The ICON 2000 actuator can be totally the actuator characteristics, service, and set-up mode�...
  • Page 23: 6�3 Entering The View Mode

    Biffi ICON 2000 InstructIon and operatIng manual 6.3 enterinG the View Mode All settings are automatically saved to a non-volatile memory and retained also if the The existing actuator configuration should electrical power is removed from the actuator� be checked before commissioning� The...
  • Page 24 Biffi ICON 2000 InstructIon and operatIng manual The figure below shows the procedure to enter view and set-up mode�...
  • Page 25 Biffi ICON 2000 InstructIon and operatIng manual 7� SET-uP MENu...
  • Page 26 Biffi ICON 2000 InstructIon and operatIng manual The figure below shows the procedure to move in the set-up routines�...
  • Page 27: View Menu

    Biffi ICON 2000 InstructIon and operatIng manual 8� VIEW MENu...
  • Page 28 Biffi ICON 2000 InstructIon and operatIng manual The figure below shows the procedure to move in the view routines�...
  • Page 29 Biffi ICON 2000 InstructIon and operatIng manual 9� SET-uP ROuTINES close limit by position Before leaving the stroke limits routine the • Move the local selector to LOCAL. The local microprocessor calculates the new value of 9.1 actuator set-up controls can be used� the position resolution� If the stroke turns • Move the valve to closed position (by CLOSE...
  • Page 30 Biffi ICON 2000 InstructIon and operatIng manual 9.1.3 esd control - Local selector in LOCAL� Choosing • Press YES if the control mode is correct or ESD > LOCAL CONTROLS, the ESD NO to scroll the list of available options: An ESD signal can be connected to the actuator 4 wires, 3 wires, 2 wires, off�...
  • Page 31 Biffi ICON 2000 InstructIon and operatIng manual 9.1.5 local controls configuration procedure The monitor relay is normally energized and This routine allows: will be de-energized on: • Move the local selector to OFF and then simultaneously press OPEN and STOP� - To configure the control mode by means...
  • Page 32 Biffi ICON 2000 InstructIon and operatIng manual default #1 configure output relays The “position request R%” signal may either be Monitor relay • Press YES to change the monitor received from the bus or the 4-20 mA analog - main voltage failure relay or NO to change auxiliary relays input� If the ICON 2000 is set to receive the - lost phase AS1, 2, 3, 4, 5, 6, 7, 8�...
  • Page 33 Biffi ICON 2000 InstructIon and operatIng manual The curves below may better clarify the above • Press YES if the configured value of the The following options can be configured: option: % MIN is correct (from 0 to 75%), or press NO - Action: open, close, stay-put, go to position %, to change it, then press yES� The standard no action (Off)� example a value is 0�...
  • Page 34 Biffi ICON 2000 InstructIon and operatIng manual configuration procedure configuration procedure configuration procedure • Move the local selector to OFF and then • Move the local selector to OFF and then • Move the local selector to OFF and then simultaneously press OPEN and STOP� Select simultaneously press OPEN and STOP� Select simultaneously press OPEN and STOP� Select the language and then enter the password...
  • Page 35 Biffi ICON 2000 InstructIon and operatIng manual 9.1.11 2-speed timer On time On time On time The “2-speed timer” routine is used to extend Motor time time time the actuator travelling time in opening and/or closing direction, by driving the motor by...
  • Page 36 Biffi ICON 2000 InstructIon and operatIng manual 9.1.13.2 factory settings The above routine resets the present configuration and restores the default configuration as below: Stroke limits Close direction: CW Close limit: by position Open limit: by position Torque set-up Closing torque: 40%...
  • Page 37: Valve Data

    Biffi ICON 2000 InstructIon and operatIng manual 9.1.13.4 lithium battery 9.1.13.6 Valve jammed (time) 9.2.1 sample configuration procedure On request, the actuator can be provided with The valve jammed time is used to monitor the tag name a lithium battery to update the remote outputs...
  • Page 38: Maintenance

    Biffi ICON 2000 InstructIon and operatIng manual 9.3 Maintenance clearing procedure • Press NO to scroll the list of available routines and then press yES to select clear • Move the local selector to OFF and then A large amount of data is stored in the actuator alarm log� simultaneously press OPEN and STOP� • Press YES to clear alarm log. Select the language and enter the password...
  • Page 39 Biffi ICON 2000 InstructIon and operatIng manual 9.3.6 set maintenance date configuration procedure The maintenance date routine allows the • Move the local selector to OFF and then following operations: simultaneously press OPEN and STOP� Select - to set the last maintenance date the language and then enter the password - to set the next maintenance date according to the instructions (see “Entering...
  • Page 40: Example Of Set-Up Routine

    Biffi ICON 2000 InstructIon and operatIng manual 9.4 exaMple of set-up routine 9.4.1 torque set-up local reMote TORQuE SETuP SETuP MODE ACTuATOR SETuP STROKE LIMIT CHANGE? CHANGE? CHANGE? 3-position selector display XXXXXX CLOSING TORQuE OPENING TORQuE Press NO STOP NEXT? 55% OK?
  • Page 41: View Routines

    Biffi ICON 2000 InstructIon and operatIng manual 10� VIEW ROuTINES routine parameters Stroke limits Close direction (CW, CCW), close limit type (torque or position), open limit type 10.1 actuator set-up (torque or position) Torque set-up Closing torque limit %, opening torque limit % The above menu allows to view the present...
  • Page 42: Maintenance

    Biffi ICON 2000 InstructIon and operatIng manual 10.4 Maintenance The following data may be viewed: curves in opening and closing relevant to the Closing torque last 200 valve strokes with the torque curve 10.4.1 alarm log - Breakout % reference saved before�...
  • Page 43 Biffi ICON 2000 InstructIon and operatIng manual The amount of data to be viewed is large and the local display can only visualize one datum at a time� To use this function we suggest to utilize the features available with PDA’s and PC through Bluetooth™...
  • Page 44 Biffi ICON 2000 InstructIon and operatIng manual Data logger modes: Opening time This datum is only available in the general data log� It is updated at the end of every • OFF: the data logger is not active. full valve stroke of the valve in opening direction� The data of the previous stroke are • RECORDER mode: the ICON 2000 measures...
  • Page 45 Biffi ICON 2000 InstructIon and operatIng manual The figure below shows a graph with sampling • EVENT mode: the ICON 2000 detects the time 2 secs in RECORDER mode� type of received command (OPEN or CLOSE), the source of the command (local controls, remote controls, bus, etc�) and date and time of command�...
  • Page 46: 10�5 Example Of View Routine

    Biffi ICON 2000 InstructIon and operatIng manual 10.5 exaMple of View routine 10.5.1 View torque set-up local reMote TORQuE SETuP STROKE LIMIT VIEW MODE ACTuATOR SETuP VIEW? VIEW? VIEW? 3-position selector display XXXXXX CLOSING TORQuE STOP NEXT? 55% NEXT? STOP to setup...
  • Page 47: Maintenance

    Biffi ICON 2000 InstructIon and operatIng manual 11� MAINTENANCE • Check that all nuts and bolts securing the actuator to the valve are tight� If necessary, 11.1 standard Maintenance re-tighten with a dynamometric key (for tightening torque values see paragraph 3�4�3, Approx� every 2 years: Installation - Mounting the actuator onto the under normal operating conditions, the valve - Actuator fixing)�...
  • Page 48: 11�3 Lithium Battery Change

    Biffi ICON 2000 InstructIon and operatIng manual 11.3 lithiuM Battery chanGe warninG If the actuator is located in a hazardous area a • Isolate the main supply to the actuator and all “hot work” permit must be obtained unless the other control voltages� actuator can be moved to a non-hazardous area.
  • Page 49: Troubleshooting

    Biffi ICON 2000 InstructIon and operatIng manual 12� TROuBLESHOOTING The ICON 2000 actuator has passed the functional test performed by Biffi Quality Assurance personnel� warninG The actuator is non-intrusive. The control compartment was sealed in dry and clean conditions and contains no site serviceable components.
  • Page 50: The Motor Runs But The Actuator

    Biffi ICON 2000 InstructIon and operatIng manual 12.6 the Manual oVerride cannot Be enGaGed In case the engagement of the lever is too difficult, check whether the drive sleeve is stuck and proceed as follows: • Open the cover. • Try to move the drive sleeve by a screw-driver� • Reassemble the cover. 12.7 the ValVe does not seat correctly 12.9 the actuator does not stop in...
  • Page 51: 12�11 Diagnostic Messages

    Biffi ICON 2000 InstructIon and operatIng manual 12.11 diaGnostic MessaGes alarm is the condition that occurs when a View procedure variable is outside the acceptable range and • Move the 3-position selector to either OFF or The alarm and warning lists contain the alarms some actuator function is not available� If the REMOTE, then press NO to scroll the list of and warnings momentarily present�...
  • Page 52 Biffi ICON 2000 InstructIon and operatIng manual alarM taBle available controls display message condition for alarm action local remote alarm reset High torque in Measured torque greater than the Operate the actuator in opening Only open Only open Configuration Open control...
  • Page 53: Parts List And Drawings

    Biffi ICON 2000 InstructIon and operatIng manual warninG taBle available controls display message condition for warning action local remote warning High torque in OP Measured torque 10% lower than the Check the torque necessary to Available Available Available Close control (near max�) relevant value configured in torque...
  • Page 54 Biffi ICON 2000 InstructIon and operatIng manual COMPONENT PARTS taBle 1 - coMponent parts item description item description item description Housing Handwheel Screw Lower bearing Oil plug Position sensor flange Hollow shaft Screw 47 * Position sensor assembly Worm wheel...
  • Page 55 Biffi ICON 2000 InstructIon and operatIng manual ELECTRIC MOTOR taBle 2 - electric Motor item description 25�1 * Electric motor 25�2 Speed magnetic sensor 25�3 Spring 25�4 Screw 25�5 * Speed magnetic card assembly 25�6 Screw 25�1 25�7 Motor terminals board 25�8...
  • Page 56 Biffi ICON 2000 InstructIon and operatIng manual LEVER ASSEMBLy taBle 4 - leVer asseMBly item description 36�1 Lever 36�2 36�3 Shoulder washer 36�4 Bearing 36�1 36�5 Spring 36�2 36�6 Retainer ring 36�7 36�3 36�4 36�5 36�6 36�7 POSITION SENSOR ASSEMBLy...
  • Page 57 Biffi ICON 2000 InstructIon and operatIng manual LOCAL INTERfACE ASSEMBLy taBle 6 - local interface asseMBly item description 55�1 * Ball 55�2 * Spring 55�3 * O-ring 55�4 * Selector 55�5 * Screw 55�6 * Plug * Recommended spare parts 55�1...
  • Page 58 All Pentair trademarks and logos are owned by Pentair plc� All other brand or product names are trademarks or registered marks of their respective owners� Because we are continuously improving our products and services, Pentair reserves the right to change product designs and specifications without notice�...
  • Page 59 Biffi ICON 2000 / ICON 2000 AD Addendum A to InstructIon And operAtIng mAnuAl c Ex d e IIB+H2 T4 Gb / c Ex tb IIIC T135°C Db IP66/68 c Ex d e ia IIB+H2 T4 Gb / c Ex tb IIIC T135°C Db IP66/68 1�...
  • Page 60 Biffi ICON 2000 / ICON 2000 AD Addendum A to InstructIon And operAtIng mAnuAl 2� CHECk fOR RIGHT 3� APPlICABlE GENERAl 4� TERMS AND CONDITIONS APPlICATION STANDARDS AND Biffi guarantees each single product to be free REGulATIONS from defects and to conform to current goods WArning specifications�...
  • Page 61 Biffi ICON 2000 / ICON 2000 AD Addendum A to InstructIon And operAtIng mAnuAl 6� STORAGE AND 7.1 Working CondiTion iMporTAnT When alternative entries are used, indication PRE-INSTAllATION WArning of the dimensions is imprinted directly on the For the correct utilization with respect to the housing close to the entry.
  • Page 62 Biffi ICON 2000 / ICON 2000 AD Addendum A to InstructIon And operAtIng mAnuAl External earth stud Entries from A to k Internal earth stud 7.2.3 Base actuator with extensions [B] or [C] Two earth points of connection, one internal...
  • Page 63 All Pentair trademarks and logos are owned by Pentair plc� All other brand or product names are trademarks or registered marks of their respective owners� Because we are continuously improving our products and services, Pentair reserves the right to change product designs and specifications without notice�...
  • Page 64 Biffi ICON 2000 / ICON 2000 AD Addendum B to InstructIon And operAtIng mAnuAl ATEX: c Ex d IIB T4 Gb / c Ex tb IIIC T135°C Db IP66/68 c Ex d ia IIB T4 Gb / c Ex tb IIIC T135°C Db IP66/68 IECEx: Ex d IIB T4 Gb / Ex tb IIIC T135°C Db IP66/68...
  • Page 65 Biffi ICON 2000 / ICON 2000 AD Addendum B to InstructIon And operAtIng mAnuAl 2� CHECk fOR RIGHT 3� APPlICABlE GENERAl 4� TERMS AND CONDITIONS APPlICATION STANDARDS AND Biffi guarantees each single product to be free REGulATIONS from defects and to conform to current goods WArning specifications�...
  • Page 66 Biffi ICON 2000 / ICON 2000 AD Addendum B to InstructIon And operAtIng mAnuAl 6� STORAGE AND 7.1 Working CondiTion PRE-INSTAllATION WArning For the correct utilization with respect to the 6.1 STorAge proCedure safety and the functionality of the enclosures components, check the "temperature ambient...
  • Page 67 Biffi ICON 2000 / ICON 2000 AD Addendum B to InstructIon And operAtIng mAnuAl External earth stud Entries from A to k Internal earth stud 7.2.3 Base actuator with extensions [B] or [C] Two earth points of connection, one internal...
  • Page 68 All Pentair trademarks and logos are owned by Pentair plc� All other brand or product names are trademarks or registered marks of their respective owners� Because we are continuously improving our products and services, Pentair reserves the right to change product designs and specifications without notice�...
  • Page 69 Biffi ICON 2000 / ICON 2000 AD Addendum C to InstruCtIon And operAtIng mAnuAl c Ex d IIC T4 Gb / c Ex tb IIIC T135°C Db IP66/68 c Ex d ia IIC T4 Gb / c Ex tb IIIC T135°C Db IP66/68 On the compartment containing the intrinsic safety circuit, the marking: Ex ia IIC T4 Ga 1�...
  • Page 70: Terms And Conditions

    Biffi ICON 2000 / ICON 2000 AD Addendum C to InstruCtIon And operAtIng mAnuAl Normally the optional extension for additional IECEx INE XX�ZZZZ IECEx reference certificate (CoC) entry/entries or additional electronic card XX ATEX ZZZZ ATEX reference certificate are directly mounted on the base ICON 2000 /...
  • Page 71: Working Condition

    Biffi ICON 2000 / ICON 2000 AD Addendum C to InstruCtIon And operAtIng mAnuAl 7� INSTAllATION iMpOrTAnT When alternative entries according ISO 965 are iMpOrTAnT used, indication of the dimensions is imprinted on The installation must be carried out in accordance...
  • Page 72: Maintenance

    All Pentair trademarks and logos are owned by Pentair plc� All other brand or product names are trademarks or registered marks of their respective owners� because we are continuously improving our products and services, Pentair reserves the right to change product designs and specifications without notice�...
  • Page 73 Biffi ICON 2000 / ICON 2000 AD Addendum d to InstructIon And operAtIng mAnuAl c Ex d e IIC T4 Gb / c Ex tb IIIC T135°C Db IP66/68 c Ex d e ia IIC T4 Gb / c Ex tb IIIC T135°C Db IP66/68 1�...
  • Page 74 Biffi ICON 2000 / ICON 2000 AD Addendum d to InstructIon And operAtIng mAnuAl Normally the optional extension for additional IECEx INE XX�ZZZZ IECEx reference certificate (CoC) entry/entries or additional electronic card XX ATEX ZZZZ ATEX reference certificate are directly mounted on the base ICON 2000 /...
  • Page 75 Biffi ICON 2000 / ICON 2000 AD Addendum d to InstructIon And operAtIng mAnuAl 7� INSTAllATION iMpOrTAnT When alternative entries according ISO 965 are iMpOrTAnT used, indication of the dimensions is imprinted on The installation must be carried out in accordance...
  • Page 76: Periodic Inspections

    All Pentair trademarks and logos are owned by Pentair plc� All other brand or product names are trademarks or registered marks of their respective owners� because we are continuously improving our products and services, Pentair reserves the right to change product designs and specifications without notice�...
  • Page 77: Marking

    Biffi ICON 2000 / ICON 2000 AD Addendum e to InstructIon And operAtIng mAnuAl c Ex d e IIB T4 Gb / c Ex tb IIIC T135°C Db IP66/68 c Ex d e ia IIB T4 Gb / c Ex tb IIIC T135°C Db IP66/68 1�...
  • Page 78: Terms And Conditions

    Biffi ICON 2000 / ICON 2000 AD Addendum e to InstructIon And operAtIng mAnuAl IECEx INE XX�ZZZZ IECEx reference certificate (CoC) Normally the optional extension for additional XX ATEX ZZZZ ATEX reference certificate entry/entries or additional electronic card 0080 Notified body for ATEX quality assurance (INERIS)
  • Page 79: Working Condition

    Biffi ICON 2000 / ICON 2000 AD Addendum e to InstructIon And operAtIng mAnuAl 7� INSTAllATION iMpOrTAnT When alternative entries according ISO 965 are iMpOrTAnT used, indication of the dimensions is imprinted on The installation must be carried out in accordance...
  • Page 80: Maintenance

    All Pentair trademarks and logos are owned by Pentair plc� All other brand or product names are trademarks or registered marks of their respective owners� Because we are continuously improving our products and services, Pentair reserves the right to change product designs and specifications without notice�...

Table of Contents