Temperature Control

From the SolarTouch
setting using the Less (Down arrow) button or More (Up arrow) button. After the target
temperature is reached, the solar system will automatically switch off or when solar energy
is no longer available.
Setting the Water Target Temperature for Pool or Spa
(see Main Menu on page 3)
To set the water target temperature, press the Less (Down arrow) button or More (Up
arrow) button to lower or raise the set target temperature to the desired level. The set
temperature can be adjusted from 40° F to 104° F (4° C to 40° C). This sets the solar
system to heat the water up to the target temperature when enough solar energy is
available.

Normal Operating Mode

In normal operating mode the main screen displays the current WATER temperature,
TARGET Temperature and if SOLAR HEAT, NOCTURNAL COOLING or FREEZE is ON
or OFF. Press the Enter button to view the current water and solar temperatures. Degree
units are displayed in either Fahrenheit or Celsius (see Advanced menu, page 5).
Effective solar heat depends on the solar and water temperature and the start and stop
differentials, then SolarTouch controller will rotate the positive 3-way valve and turn on the
solar booster pump or increase the RPM's if an IntelliFlo
This allows the water to flow to the solar collectors.
The solar roof sensor must be 6° higher than the water temperature. The pump must be
ON for a few minutes for operation. When the roof sensor and the water temperature are
within 3° of each other, solar heat will switch off. The solar temperature start and stop
differential settings are factory set at 6° and 3°. These differential settings are adjustable
in the Advanced Menu settings. Refer to your solar service professional for the optimum
setting.
Note: For more Information about daily pool filtering schedules and time clock
override see page 12.
SolarTouch
Solar Control System Installation and User's Guide
®
Controller control panel you can set the desired target temperature
®
Less (Down arrow) button - More (Up arrow) button
or IntelliPro
Pump is present.
®
®

Advertisement

Table of Contents
loading

This manual is also suitable for:

Solartouch 521632Solartouch 521942

Table of Contents