Pentair Onga WaterSwitch WS1500200 Owner's Manual

Pentair Onga WaterSwitch WS1500200 Owner's Manual

Automatic rainwater controller

Advertisement

WaterSwitch
Automatic Rainwater Controller
Please read Owner's Manual before installation
Should the installer or owner be unfamiliar with the
correct installation or operation of this type o f
equipment, contact the distributor or manufacturer
for correct advice before proceeding with installation
or operation of the product
Distributed in NZ By:
WS1500200
C of C: 40087 in accordance
with ATS5200.477-2006
Freephone 0508 634 341
7 Monier Pl, Mt Wellington, Auckland
1060, New Zealand

Advertisement

Table of Contents
loading

Summary of Contents for Pentair Onga WaterSwitch WS1500200

  • Page 1 WaterSwitch Automatic Rainwater Controller WS1500200 C of C: 40087 in accordance with ATS5200.477-2006 Please read Owner’s Manual before installation Should the installer or owner be unfamiliar with the correct installation or operation of this type o f equipment, contact the distributor or manufacturer for correct advice before proceeding with installation or operation of the product Distributed in NZ By:...
  • Page 2 As a global leader in water products, Pentair Water is making a strong commitment to develop the most environmentally responsible products available. The new Eco-Select label is the keystone of this green program to meet the dual objectives of a growing number of home owners - to save money and make more eco-friendly choices.
  • Page 3 WaterSwitch Installation Instructions The operator must be provided with this owner’s manual. This must be read before installation and followed during installation. These instructions are a guide only. Users not familiar with the installation and maintenance of electrical and pumping equipment should seek advice from people with experience in pump installation and operation.
  • Page 4: Table Of Contents

    Table of Contents Page Model Data Application Installation Water Level Sensor Installation OInformer WaterSwitch Electrical Connection Operation Fault Mode Service and Maintenance Troubleshooting Installation of Complete WaterSwitch System...
  • Page 5: Model Data

    Model Data Technical Information Mains Water Supply inlet: 1” BSP thread Pump connection: 1” BSP thread Water outlet connection: 1” BSP thread To toilet, garden, laundry Mains Supply From Pump Grip and Brace the connection while fi tting pipework Minimum Mains Pressure: 100 kPa Maximum Mains Pressure: 1000 kPa...
  • Page 6: Application

    Application WaterSwitch is designed to select between stored rainwater (when available) and mains supply water, and send this water to your toilet cistern, washing machine, garden and other non-potable household applications. It features automatic pump control to minimise the use of electricity while saving water. Rain water is used in preference so that: - your water rates are minimised - you conserve mains water and reduce usage of the city catchments water supply...
  • Page 7: Installation

    Preparation for installation Read these instructions first. Inspect WaterSwitch for shipping damage. Report any damage to your Pentair Water dealer. If the incoming mains pressure to your property is greater than the specifi ed 1000 kPa, please fit a pressure reduction valve of appropriate capacity upstream of WaterSwitch.
  • Page 8 Installation Fittings and accessories Ensure that you have all required fittings and accessories prior to installing WaterSwitch. Surface Pumps For installation using ¾” copper tube we recommend the following items: - threadseal tape - ¾” flare – 1” BSP Male brass connectors [x2] - WaterSwitch Surface (Float) Kit 707170 For installation using polyethylene tube, we recommend the following items - threadseal tape...
  • Page 9 Installation Installation Recommendations 1. The Onga WaterSwitch comes with 2 mesh inline filters. These fi lters should be correctly inserted on the mains water input and pump input of the WaterSwitch. 2. Onga recommends the height of the tank outlet from the base of the tank be set at 100mm.
  • Page 10 Installation Connecting the WaterSwitch to the Pump Using the Union Kit (Where Supplied) 1. Wrap a sufficient amount of thread seal tape around both ends of the 1” Nipple. 2. Connect one end of the nipple into the pump discharge, threading it until it is watertight.
  • Page 11: Water Level Sensor Installation

    Water Level Sensor Installation Float Sensor Installation 1. Determine a suitable position in the tank roof within reach of the man-hole, to drill a 16mm hole for switch cable penetration. (Note: Hole saw available from Onga dealer). Install the supplied cable gland, with the Locknut positioned inside the tank. 2.
  • Page 12: H 2 Oinformer

    H OInformer Manual Status Override The WS1500200 model WaterSwitch is equipped with the H OInformer. The H OInformer allows you to see your actual water saving. The H OInformer can be detached from the WaterSwitch and be placed conveniently in the kitchen or other room within 20 metres of the WaterSwitch and will continue to give up to date water readings as you require them.
  • Page 13 H OInformer H OInformer Display Options The following information can be viewed by using the “mode” button to scroll through the menu 1. Rain water usage in litres (indicated by tank icon) 2. Mains water usage in litres (indicated by tap icon) 3.
  • Page 14: Waterswitch Electrical Connection

    The supply voltage for the WaterSwitch must be within the stated parameters. Refer to page 3 of the owner’s manual. If the power supply cord or pump interconnection cord is damaged, it must be replaced by an authorised Pentair Water Service Agent or a similarly qualified person in order to avoid hazard.
  • Page 15: Operation

    Operation Commissioning Put a small amount of water in the tank (just above the level of the tank sensor). Open a tap on the outlet side of the WaterSwitch (or have someone flush the toilet). The pump will start. Turn off the tap, and the pump will stop. Temporarily disconnect the level sensor connection (fitting in base).
  • Page 16: Fault Mode

    Fault Mode WaterSwitch has a mechanism to prevent the pump from running with no water. If the level sensor detects water in the tank, but there is a blockage or partial blockage somewhere in the system the following process will occur: 1.
  • Page 17: Service And Maintenance

    Ensure that your property is vermin free. WaterSwitch is electrically connected. Ensure that it is isolated from electrical supply during installation and any subsequent service work. WaterSwitch should only be serviced by a Pentair Water service agent. WaterSwitch Service Before removing WaterSwitch for service: 1.
  • Page 18: Troubleshooting

    Troubleshooting Symptom Cause Remedy Check tank level, wait for rain Water tank is empty if empty Check power supply, circuit No power at outlet breakers and plug. Check installation and operation Bad signal from level sensor of the level sensor. No water is being Pump has overheated Allow pump to cool...
  • Page 19 Troubleshooting Symptom Cause Remedy Bleed air from system. Activate appliances/outlets sequentially from the nearest to the furthest Air lock in system outlet. Repeat if necessary. If Pump continually runs problem persists contact your dealer. Switch off power for 10 seconds. Turn power on and Not correctly paired to hold down manual reset on WaterSwitch...
  • Page 20: Installation Of Complete Waterswitch System

    Installation of Complete WaterSwitch System Pump Cover Kit installation 1. Place Pump/Cover assembly in position required for installation and remove cover, 2. Install all necessary pipework for Mains, House/Garden and Tank supply. 3. Please flush clean pipe work to waterswitch before connection. 4.
  • Page 21 Notes...
  • Page 22 Notes...
  • Page 23 Notes...
  • Page 24 IMPORTANT Please attach your sales invoice/docket here as proof of purchase should warranty service be required. Please do not return Warranty - Retain for your records. Purchased From ........................Purchase Date........Serial No......Model No......Distributed in NZ By: Freephone 0508 634 34 1 7 Monier Pl, Mt Wellington, Auckland 1060, New Zealand...

Table of Contents