Error messages

10.2 Cooking chamber sensor defective (694, 695)

Description Emergency operation is activated automatically and displayed. The
core temperature sensor takes over the function of the cooking
chamber sensor. Cooking program with core temperature sensor is
no longer available.
Naming on the circuit
B2
diagram
Troubleshooting
Check contacting from cooking chamber sensor to control board A1 X25. Error eliminated?
Remove existing cooking chamber sensor from the control board A1 X25 and plug in new cooking
chamber sensor. Error eliminated?
No
Yes
Replace control board.
Replace cooking chamber sensor.
Function check The measurement values can be called up in the status overview.