5.8 DynaSteam test

Description The DynaSteam test allows the function test of the DynaSteam
Prerequisite Access to the water supply pipe in the cooking chamber.
Overview
Starting the test
Check the water quantity Collect the water from the supply pipe with a measuring container.
steaming unit.
Calibration of the steaming unit is not possible / necessary.
Remove both hook-in points.
Dismount water supply pipe.
Dismount air diverter.
Replace water supply pipe.
Touch "Initialization" field.
Automatic pre-rinse.
Field changes to "START".
Set water quantity using the rollers.
Touch the "START" field.
Activation of the DynaSteam steaming unit.
The water comes runs from the water supply pipe into the
cooking chamber.
Starting water test.
After the predetermined amount of water has gone through, the
steaming unit stops automatically.
Compare amount of water with the set value. A deviation of +-
10% is within tolerance.