Fan Defective. Cooking Program Was Cancelled (701); Fan_Id23: Fan Error: Attempt To Restart; Overview; Troubleshooting - Henny Penny SpaceSaver Plus Team Service Instructions Manual

Table of Contents

Advertisement

Error messages

10.9 Fan defective. Cooking program was cancelled (701)

Description The control board A1 does not receive any response via the CAN bus

Troubleshooting

10.10 FAN_ID23: Fan error: Attempt to restart

10.10.1 Overview

10.10.2 Troubleshooting
DANGER
60
cable from power board T10.
w
v
u
b
L1
d
a
N
PE
a Fuse F1 6.3 A
c Connector S300. Motor power
supply
e Connector S500. CAN connection
to control circuit board
Warning: electric shock! Danger of death!
When working on the power board, make sure that energized parts are ex-
posed. Work on these components during operation and up to 3 minutes after
enabling is not allows. Even if the motor is stopped and the appliance is de-en-
ergized, the connection terminals and components can conducted dangerous
voltage!
Service instructions
c
f
e
b Power board
d Connector S100. Power supply
circuit board
f Connector S501. Input for
temperature switch from motor
g

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fsde 610.610

Table of Contents