Combidoctor - Henny Penny SpaceSaver Plus Team Service Instructions Manual

Hide thumbs Also See for SpaceSaver Plus Team:
Table of Contents

Advertisement

Service menu - appliance test
Miscellaneous

5.4 CombiDoctor

Description The CombiDoctor offers an automatic check of the climate control
Overview
Selecting a program
Starting the program
Evaluation
Description of the test
18
Status 4
K3: Not in use
K10: Activation of the exhaust hood at high speed (option)
B15: Reed contact switch
K07, K13, K14: Not used
Temperature sensors B1, B3, B5, B6, B7 are not present.
and the WaveClean automatic cleaning. The tests are possible
individually or as overall test. For instructions on performing, see the
touchscreen.
Select a program by adjusting the roller.
Touch the "START" field.
The test result appears on the touchscreen.
Entry in HACCP memory.
Step 1 (test door contact)
steps
1. Open cooking chamber door and close again.
If test successful, proceed with the next test step.
If the door is not recognized as having been opened and
closed again within the specified time (60 seconds), the test is
not passed.
Step 2 (prepare for WaveClean)
1. Preparation for WaveClean test.
Automatic water exchange via the siphon pump and the solenoid
valve for steam elimination.