Service menu - appliance test
5.7 100°C + core temperature calibration
Description
INFORMATION
Overview
Color detection of the
temperature values
INFORMATION
24
Calibration for cooking chamber sensor and core temperature
sensor.
Testing the calibration.
Performing the calibration.
The cooking chamber sensor and core temperature sensor calibration
is performed in one step.
The units are factory calibrated. Recalibration is required only in exceptional
cases.
j
a
b
c
d
e
f
a Back to the unit test
b Not used
c Cooking chamber temperature
d Saved offset
e Average heat requirement
During calibration, the temperatures are displayed in color:
Red = temperature in invalid calibration range
Green = temperature in valid calibration range
Service instructions
i
g
f Core temperature measurement
values
g Save changed offset
h Help function (not used)
i Offset setting
j "Start/Stopp" field
h