Error messages
10.11.2 Troubleshooting
Is the fault message displayed continuously?
Check sieve on the water connection for soiling. To
do this, remove the on-site water connection to the
unit.
For additional troubleshooting, swing out the air
diverter in the cooking chamber.
Perform the DynaSteam test in the Service menu.
Does water run through the water supply pipe into
the cooking chamber?
Perform DynaSteam test again and check water
quantity with measurement container.
Perform DynaSteam test again and check water
quantity with measurement container.
Does the water quantity correspond to the set
quantity (± 10 %)?
Replace pressure switch.
10.12 Water pressure during WaveClean too low
10.12.1 Description
Description This fault message is displayed if the pressure switch registered a
62
Soft water connection attached and water valve at site open?
Yes
Yes
Yes
Yes
water pressure that is too low during WaveClean. The program is
stopped until the water pressure is sufficiently high again.
Service instructions
No
Connect water supply or open water valve.
No
Check the on-site water pressure while observing
nearby water consumers.
No
Check water supply pipe for calcification.
Ensure that the hose between the steaming unit and
supply pipe is not clogged.
Replace steaming unit.
No
Ensure that the supply pipe is not clogged. Check
whether the fault still appears.
Yes
Replace steaming unit.