Henny Penny SpaceSaver Plus Team Service Instructions Manual page 20

Table of Contents

Advertisement

Service menu - appliance test
20
Step 8 (WaveClean siphon pump)
1. Check of WaveClean siphon pump.
Display switches to green = test successful.
Display switches to red = test not successful.
Check of siphon pump via relay test. A fault is present on the
component or the control board. Check the fuse on the control
board.
Step 9 (temperature control)
1. Check of temperature control.
The temperature in the cooking chamber must reach 140°C
within the time specified.
Display switches to green = test successful.
Display switches to red = test not successful.
Check region around cooking chamber sensor for soiling.
Check temperatures via calibration in the service menu.
If necessary, replace cooking chamber sensor or control board.
Service instructions

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fsde 610.610

Table of Contents