11.4. Preventative maintenance programme
7DAY
QUAR
ANNUAL
50 h
600 h
2400h
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
Maintenance
PROCEDURES RESERVED EXCLUSIVELY FOR THE CUSTOMER'S
TECHNICAL SERVICES OR AUTHORISED TECHNICAL SERVICES
Check the heating system ignition and combustion (gas heating)
Clean the lint filter
Clean the protective vents of the extraction motor fan
Clean the extraction turbine blades and the exhaust ducts.
Clean the inverter fan
Clean the inside of the machine
Clean the inverter fan and heatsink (only if considered necessary).
Check the static pressure at the fan output.
REQUEST AN ANNUAL SERVICE FROM AUTHORISED TECHNICAL
SERVICES
Check all the functions of the dryer (TEST program)
Check the heating system
Check the power consumption of the drum motor and the extraction motor
Check the power consumption of the electric heaters (electric heating)
Check and clean the burner (gas heating)
Check the rotation detector
Check external protections and electrical earthing
Check the gas tightness of the gas circuit (gas version)
Check the condition of the nuts and bolts
Clean the lint from the machine and from the exhaust area.
Analysis of the combustion products THE RESULT MUST COMPLY WITH
THE REQUIREMENTS IN FORCE IN THE COUNTRY WHERE THE DRYER
IS INSTALLED.
47
Code no. 576017
Rev. nº 02/0415