11.4. Preventative maintenance programme

7DAY
QUAR
ANNUAL
50 h
600 h
2400h
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
Maintenance
PROCEDURES RESERVED EXCLUSIVELY FOR THE CUSTOMER'S
TECHNICAL SERVICES OR AUTHORISED TECHNICAL SERVICES
 Check the heating system ignition and combustion (gas heating)
 Clean the lint filter
 Clean the protective vents of the extraction motor fan
 Clean the extraction turbine blades and the exhaust ducts.
 Clean the inverter fan
 Clean the inside of the machine
 Clean the inverter fan and heatsink (only if considered necessary).
 Check the static pressure at the fan output.
REQUEST AN ANNUAL SERVICE FROM AUTHORISED TECHNICAL
SERVICES
 Check all the functions of the dryer (TEST program)
 Check the heating system
 Check the power consumption of the drum motor and the extraction motor
 Check the power consumption of the electric heaters (electric heating)
 Check and clean the burner (gas heating)
 Check the rotation detector
 Check external protections and electrical earthing
 Check the gas tightness of the gas circuit (gas version)
 Check the condition of the nuts and bolts
 Clean the lint from the machine and from the exhaust area.
 Analysis of the combustion products THE RESULT MUST COMPLY WITH
THE REQUIREMENTS IN FORCE IN THE COUNTRY WHERE THE DRYER
IS INSTALLED.