List Of Main Alarms; Troubleshooting - GIRBAU ED260 Operation And Maintenance Instruction Manual

Ed coin dryers
Table of Contents

Advertisement

10.2.1. List of main alarms

CODE
2
Assembly error
3
Inverter communication fault
4
Inverter overcurrent
5
Motor overheating
6
General inverter fault
7
Inverter configuration fault
8
Lint door open
9
Overtemperature
10
Heating fault
11
Input temperature probe

10.2.2. Troubleshooting

2
ASSEMBLY ERROR
Incorrect microprocessor board connections.
Probable cause:
Incorrect connections or manipulation of the microprocessor board.
Procedure:
Disconnect the power supply and contact Authorised Technical Services.
3
INVERTER COMMUNICATION FAULT
Communication fault between the dryer control microprocessor and the drum motor inverter.
Probable cause:
Fault in the electrical supply from the inverter.
Fault in the communication wiring.
Fault in the inverter's communication circuits or the microprocessor.
Procedure:
Disconnect the machine from the power supply and reconnect it.
If fault persists, disconnect the power supply and contact Authorised Technical Services.
ALARMS
Alarms
CODE
12
Output temperature probe
13
Input thermostat alarm
14
Output thermostat alarm
15
Rotation fault
16
Gas ignition fault
17
Electric heating fault
18
Heating fault
19
Vaccuum fault
20
Fan fault
21
Model error
ALARMS
Code no. 576017
Rev. nº 02/0415
38

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents