installation
CV40E Painted Panel Installation
CV40E INNER PANELS
Inner Panels-CV40E
The CV40E can be equipped with optional steel inner panels.
CV40E - 3 outer panels and 4 inner panels.
Turn off unit and allow to cool to room temperature. Remove the safety
glass and firebox glass — see manual for instructions
1. Install inner base panels as shown.
2. Manoeuvre in back panel to the back wall of the unit.
3. Install panel bracket into the slot in the panel.
4. Slide the panel and bracket into the unit until it contacts the back panel.
Install bracket into
slot in panel
5. When side panel is in position, secure in place with one screw. The
side panel ,once installed will hold the back panel in position.
tooltip
6. Repeat steps 2-4 to install opposite panel.
7. Reverse steps to remove panels.
| CV40E-11 City Series
58
919-673
CV40E OUTER PANELS
Outer Panels-CV40E
1. Attach Regency logo to the right hand side of outer front panel. The
magnets will be positioned under the outer front base panel to secure
the logo. Install outer front base panel.
Outer front panel install
2. Install side panel - the side panel is secured in place by existing
magnets in the unit.
Outer side panel install
3. Reverse steps to remove panels.
1
CITY SERIES
Location of
Regency Logo
06.09.16