9.3
PUMP REMOVAL
1
Turn the machine OFF and unplug it, open the
left panel, remove the tank (tank version).
Take care to disconnect the ground connection
of the panel.
2
Remove the Teflon pipes from the pumping ele-
ment.
3
Tilt the machine on the right side.
4
Remove the electrical connections and the
check valve.
9.4
SERVICE MANUAL
1
2
3