8.4
ELECTRONIC CONTROL UNIT
1
To remove the electronic control unit, discon-
nect all connecting wires and three locking
screws on the frame.
2
At the right top of the unit are:
A
Fuse [6.3 A]
B
Input power transformer and motor
output
C
Flow meter
D
Level probe
E
PC communication
F
Smart card reader
G
Trim for autosteam temperature
calibration
H
Display connection
I
Motor encoder
3
On the left side:
A
Coffee boiler temperature probe
B
Input
C
Keyboard connection
4
At the center of the unit are:
A
Clock battery
B
Eprom (indicate the release of the soft-
ware loaded)
C
Heat sink
Edition 00 to 01/2018
SERVICE MANUAL
1
B
C
D
E
F
G
C
B
A
I
H
A
B
C
A
2
3
4
8.5