8.3
CAPACITOR
To replace the capacitor, switch OFF the machine
with the main switch.
1
Remove the two cables.
2
With a 13 wrench to unscrew the nut.
3
When replacing the capacitor, always check the
label values.
8.4
SERVICE MANUAL