Nuova Simonelli Microbar II Service Manual page 119

Hide thumbs Also See for Microbar II:
Table of Contents

Advertisement

WATER HARDNESS SETTING:
A
When the display show the message "Water
Hardness °Fr" press ENTER
the function.
B
Press
-
keys to increase or decrease the
water hardness.
Than, press ENTER
and return to previous menu, or press RESET
key to return to the previous menu without
saving the data.
The table shows the correspondence between the
hardness set and the used water litres, above which
the message "CARRY OUT DECALCIFICATION".
NOTE
The alarm "CARRY OUT DECALCIFICATION" does
not interrupt the machine functioning and is
reset after having carried out the decalcification
cycle together with the litre counter. When the
value set is "00", the alarm is deactivated.
Edition 00 to 01/2018
SERVICE MANUAL
key to access
key to save the data set
o
Water Hardness
Fr
o
Water Hardness
Fr
00
WATER HARDNESS °FR
1-7
8-30
31
00
WATER LITRES
1500
1000
500
Alarm disabled
12.29