Nuova Simonelli Microbar II Service Manual page 67

Hide thumbs Also See for Microbar II:
Table of Contents

Advertisement

7.3
COFFEE SOLENOID VALVE
To replace the coffee solenoid valve:
1
Open the front door and remove the ground
drawer and the water collecting tray.
2
Remove the Teflon pipe by holding the ring.
3
Remove the exhaust pipe clip and the coffee
solenoid exhaust pipe.
4
Pull out the two electrical connection wires.
Edition 00 to 01/2018