5
The coffee solenoid valve is positioned under
the coffee boiler, accessible from the right side.
7.2
REMOVING THE SOLENOID VALVE
This must be done with the machine switched OFF
and the boiler cold.
To access the service engineer must:
1
Remove the left panel.
Take care to disconnect the ground connection
of the panel.
2
Remove the condenser exhaust pipe clip and
pipe.
NOTE
This procedure is for frother solenoid valve only;
all other solenoids valves are 2 way valves.
3
Remove the coil's two power wires.
Edition 00 to 01/2018
SERVICE MANUAL
2
3
7.3