Blade Ejector Worm Screw And Blade Ejector Removal - Nuova Simonelli Microbar II Service Manual

Hide thumbs Also See for Microbar II:
Table of Contents

Advertisement

3.7
BLADE EJECTOR
WORM SCREW AND
BLADE EJECTOR REMOVAL
The blade ejector worm screw is located on the
lower support bracket of the group.
1
Once the pouring group has been removed; it
is possible to take out the blade ejector worm
screw by removing the two screws on the base
with a Phillips screwdriver.
2
To remove the blade ejector, it is necessary to
undo the screw with a 3 mm Allen wrench.
3
Gently turn the blade to free it from the shaft
and infusion chamber.
When refitting, the engineer will have to:
4
Reposition the shaft.
5
Pre-load the spring by one turn using the blade.
Edition 00 to 01/2018
SERVICE MANUAL
4
1
1
2
3
4
5
3.9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents