AINTENANCE
R
R
R
OTATE OR
EPLACE
Perform the following steps to rotate or replace the rear squeegee blade:
1. Park the machine on a level, fl at surface and turn
off.
2. Put on appropriate personal protective
equipment if the machine has recently been used.
3. Remove the vacuum hose from the rear squeegee
assembly.
4. Loosen the two middle knobs on the top of the
squeegee assembly.
5. Remove the rear squeegee assembly from the
machine.
6. Release the spring clip and remove the metal
plate from the squeegee assembly.
46
V4.0119
• Content Subject to Change
S
B
EAR
QUEEGEE
LADES
7. Remove the inner and outer squeegee blades.
8. Rotate or replace the inner and outer squeegee
blades, depending on current condition.
9. Reattach the metal plate to the squeegee
assembly and fasten the spring clip.
10. Reattach the rear squeegee assembly to its
original position and tighten the two middle
knobs. Do not over-tighten.
11. Reattach the vacuum hose to the rear squeegee
assembly and secure it with the vacuum clip.
12. Turn on the machine and press the One-Touch
button to lower the scrub deck.
13. Verify that the rear squeegee blades are lowered
to the optimal defl ection. (See
S
H
for details.)
QUEEGEE
EIGHT
A
R
DJUST
EAR

Advertisement