Power System Behavior
Startup duration varies based upon the number of library modules. After
completion, the Home screen appears on the touch screen.
Figure 3–34 Home Screen
Illustration Legend:
1 - Library Health
Check the OK indicators on all CRUs.
4.
Verify that the library health state is operational from the touch screen (see
5.
Figure
If the health state is degraded or failed, consult the troubleshooting section of the
user's guide to assist with resolving the problem.

To Validate Library Operation

Perform an operational check of replaced CRUs, as applicable:
1.
Test the panel for general operation (locate light, touch screen, open the mailslot,
and so forth).
Confirm that the library recognizes the module controller (Modules area of the
touch screen or Library area of the SL150 remote interface).
Run the offline self tests from the SL150 remote interface (refer to the StorageTek
2.
SL150 Modular Tape Library User's Guide or the Help system for instructions).
Set the SL150 library to the online state and log out of the SL150 remote interface.
3.
3-36 StorageTek SL150 Modular Tape Library Customer Replaceable Unit Guide
In a bridged library, the host will not be able to see the library
Note:
if the bridged drive ports are not enabled. Perform troubleshooting
procedures in the user's guide to resolve a bridged drive problem.
3–34) or the SL150 remote interface.