Parameter Number And Description Table - Waterco Electroheat ECO-V 17kW Installation And Operation Manual

Pool heat pump
Table of Contents

Advertisement

31 I Pool Heat Pump

Parameter Number and Description Table

Press and hold the "Set" key for 5s to enter the password setting interface; enter
"0814" to enter the parameter query interface:
Setting
Parameter Name
Code
Air conditioning temperature
01
difference
02
03
04
Cooling temperature setting
05
Heating temperature setting
Temperature setting for protection
06
against excessive exhaust temperature
Recovery temperature setting for
07
excessive exhaust temperature
08
Press current protection
09
Inlet water temperature compensation
10
Reserved
11
Defrosting cycle
12
Defrosting entry temperature
13
Defrosting time
14
Defrosting exit temperature
Defrosting environment and coil
15
temperature difference
16
Defrosting ambient temperature
17
Main expansion valve operating cycle
18
Overheat for heating target
Exhaust temperature for main
19
expansion valve regulation
20
Defrosting expansion valve opening
Main expansion valve minimum
21
opening
22
Main expansion valve mode selection
23
Main expansion valve manual levels
24
Overheat for cooling target
Enthalpy increase expansion valve
25
manual levels
Ambient temperature for enthalpy
26
increase starting
Adjustment Range Initial Value
2°C~18°C
2°C
7°C~30°C
12°C
15°C~50°C
35°C
80°C~125°C
80°C~125°C
50°C~100°C
95°C
2A~50A
20A
-5°C~15°C
0°C
20MIN~90MIN
45MIN
-15°C-1°C
-3°C
5MIN~20MIN
10MIN
1°C~40°C
20°C
0°C~15°C
5°C
0°C~20°C
17°C
20S~90S
30S
-5°C~10°C
1°C
70°C~125°C
95°C
20~450
400
50~150
80
0-manual/
1
1-automatic
20~450
350
-5°C~10°C
0°C
20~450
350
11°C~45°C
23°C
Setting
Parameter Name
Code
27
Cooling main valve mode
28
Constant temperature pump mode
29
F1
30
F2
31
F3
32
F4
33
F5
34
F6
35
F7
36
F8
37
F9
38
F10
39
Exhaust setting TP0
40
Exhaust setting TP1
41
Exhaust setting TP2
42
Exhaust setting TP3
43
Exhaust setting TP4
44
Current I limit
45
Current I down
46
Current I shutdown
Exhaust limit main expansion valve
47
down 1
Exhaust limit main expansion valve
48
down 2
Exhaust limit main expansion valve
49
down 3
Pool Heat Pump I 32
Adjustment Range Initial Value
0-ambient/
1
1-overheat
1-normally open/
1
0-closed
15~120Hz
40 Hz
15~120Hz
45 Hz
15~120Hz
50 Hz
15~120Hz
55 Hz
15~120Hz
60 Hz
15~120Hz
65 Hz
15~120Hz
70 Hz
15~120Hz
75 Hz
15~120Hz
80 Hz
15~120Hz
85 Hz
50~125°C
95°C
50~125°C
100°C
50~125°C
105°C
50~125°C
110°C
50~125°C
120°C
5~50A
16A
5~50A
18A
5~50A
20A
50~125°C
61°C
50~125°C
65°C
50~125°C
70°C

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Electroheat eco-v 21kwElectroheat eco-v 25kwEco-v

Table of Contents