15 I Pool Heat Pump

Pool Heat Pump Running Time

Most units should be sized to operate during the pool filtering cycle time of 8-12
daytime hours daily during warmer months and up to 8 hours daily during the
daytime in winter months. On warmer days the pool heat pump will run less because
the heat loss will be less.
Condensation
Your pool heat pump will accumulate condensed water (approx. 4 to 6 litres or
1 to 1.5 gallons per hour), therefore causing water to drain out of the unit base.
In order to avoid water accumulation, you may use decorative rocks around the
concrete slab or a basin under the unit. (Please note this is a normal characteristic
of a pool heat pump and not a service or warranty issue.)
A hose may be connected to the supplied spigots fitted prior to final unit installation
to direct the condensate away from the heat pump.

Pool Solar Blanket

A pool solar blanket should be used whenever possible. blankets minimize heat loss
through evaporation and conserve heat in your pool. un-blanketed pool can lose 2-3
times more heat than a blanketed pool.

Defrost Cycle

When any of the following conditions occur the electronic control of your unit will
activate a defrost mode until most of the frost from the evaporator has melted.
Condensation of water on the evaporator coil tends to frost up quicker when the
following occur.
1. When atmospheric conditions are as stated above;
2. When the evaporator is dirty;
3. When installation clearances are not respected.
defrost is activated for between 3 to 20 minutes.

INVERTER POOL HEAT PUMP CONTROLLER

This controller applies to dC inverter air source pool heat pumps, for heating.
 button Operation:
1. On/Off: Press the "
" button on the main interface to switch between the On/Off
status;
2. Mode switching: Press the "M" button on the main interface to switch between the
operation modes;
3. button locking: Press and hold the "" and "" buttons for 5S at the same time on the
main interface to lock the buttons, and the icon
buttons are locked. repeat the operation to unlock;
4. Manual defrosting: Press the "
" and "
power-on state to start forced defrosting;
5. Parameter resetting: Press the "
same time to reset the par;ameters
6. Clock setting: Press the "SeT" button on the main interface to enter the clock setting
interface. After entering the clock setting screen, the hour flashes first, and you can
use the "" or "" to adjust the hour. After the hour is set, press the "SeT" button to
enter the minute setting. After the minute is set, press the "SeT" button to complete
the clock setting and return to the main interface.
7. Timing setting: Press the "
" button on the main interface to enter the timing
setting interface. After entering the timing setting interface, the hour in the time
period 1 setting starts flashing, and you can use the "" or "" to adjust the hour.
In the adjustment process, press the "
setting until the timing setting of the two time periods is completed. Press the "SeT"
button during any time period setting to cancel the time period.
8. Other operations: Press and hold the "SeT" button for 5s to enter the password setting
interface, enter "8563" to enter the time limit setting interface, enter "9615" to enter the
manual frequency status, and enter "8866" to switch between the display frequency
(clock display window).
Pool Heat Pump I 16
will appear on the screen when the
" buttons for 5s at the same time in the
", "M" and "
" buttons for 5 seconds at the
" button to switch to the next time period